| поискавой системы для электроныых деталей |
|
LM81 датащи(PDF) 21 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
LM81 датащи(HTML) 21 Page - National Semiconductor (TI) |
|
21 / 33 page ![]() Functional Description (Continued) Extended Repetitive Interrupt Mode is shown in Figure 14 and operates in the following way: Once activated, all inter- rupts remain activated until reset by a read of the Interrupt Status Register 1. Once activated all T_CRIT_A interrupts remain activated until reset by a read of the Extended Mode Register 1. Temperature conversion data less than or equal to T LOW will activate interrupt. Interrupt will continue to be activated until the temperature data exceeds (T LOW + T HYST). Exceeding THIGH activates interrupt. Interrupt will continue to be activated at the end of a conversion until the temperature data is less than or equal to (T HIGH −THYST). T_CRIT_A interrupts are activated when the temperature exceeds T_CRIT. T_CRIT_A interrupts will no longer be activated if the temperature data at the end of a conversion is less than or equal to( T_CRIT − T HYST). Extended One-Time Interrupt Mode is shown in Figure 15 and operates in the following way: Once activated all inter- rupts remain activated until reset by a read of the Interrupt Status Register 1. Once activated all T_CRIT_A interrupts remain activated until reset by a read of the Extended Mode Register 1. An interrupt will be activated when the data of a temperature conversion is less than or equal to T LOW. Inter- rupt cannot again be activated until the data from a tempera- ture conversion is greater than (T LOW +THYST). An interrupt will be activated when the data of a temperature conversion is greater than T HIGH. Interrupt cannot again be activated until the data of a temperature conversion is less than or equal to (T HIGH −THYST). T_CRIT_A interrupt is activated when the data from a temperature conversion is greater than T_CRIT. Activation of an T_CRIT_A interrupt cannot occur until the data from a temperature conversion is less than or equal to ( T_CRIT − T HYST). Extended Comparator Mode is shown in Figure 16 and operates in the following way: Interrupt is activated when the data from a temperature conversion is less than or equal to T LOW. Interrupt is reset when the data from a temperature conversion exceeds (T LOW +THIGH). Exceeding THIGH will activate interrupt. This interrupt will be reset when data from a temperature conversion is less than or equal to (T HIGH − T HYST). T_CRIT_A interrupt is activated when the tempera- ture exceeds T_CRIT. T_CRIT_A remains active until the data from a temperature conversion is less than or equal to (T_CRIT − T HYST) resets it. DS100072-20 *Note: Interrupt resets occur only when interrupt Status Register 1 is read. FIGURE 14. Extended Repetitive Interrupt Mode DS100072-21 *Note: Interrupt resets occur only when interrupt Status Register 1 is read. FIGURE 15. Extended One-Time Interrupt DS100072-19 *Note: Interrupt resets occur only when interrupt Status Register 1 is read. FIGURE 16. Extended Comparator Mode www.national.com 21 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |