| поискавой системы для электроныых деталей |
|
2EDF7175F датащи(PDF) 21 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
2EDF7175F датащи(HTML) 21 Page - Infineon Technologies AG |
|
21 / 37 page ![]() Final datasheet 21 Rev.2.9 2024-05-16 EiceDRIVER™ 2EDi product family 2EDSx reinforced, 2EDFx functional isolated 4A/8A, 1A/2A gate drivers Device characteristics Table 25 Input-to-output isolation specification according to DIN V, VDE0884-10 (2016-06)1) in WB PG-DSO-16-30 1) VDE encompasses former VDE0884-10, IEC60747-5-5 (opto-coupler standard) Parameter Symbol Values Unit Note or Test Condition Min. Typ. Max. Maximum transient isolation voltage VIOTM 8000 – – Vpk Qualification for t = 60 s; production test with VIOTM > 10 kVpk for t =1 s Maximum repetitive peak isolation voltage VIORM 1420 – – Vpk Time Dependent Dielectric Breakdown test method Maximum isolation working voltage VIOWM 1420 – – VDC 1000 – – VRMS Partial discharge voltage VPD 4500 – – Vpk Test sequence: 10.2 kVpk for t =1s followed by partial discharge 4.5 kVpk > 1.875 × VIOWM , QPD < 5 pC; production test Maximum surge isolation voltage VIOSM 6250 – – Vpk VIOSM_test = 1.6 × VIOSM>10 kVpk; sample tested 2) 2) Surge pulse tests applied according to IEC60065-10.1 (Ed 8.0 2014), 61000-4-5, 60060-1; waveforms (1.2 µs slope, 50 µs decay) Package clearance CLR – 8.0 – mm From any input pin to any output pin Package creepage CPG – 8.0 – mm From any input pin to any output pin Overvoltage category per IEC 60664-1 table F.1 – I – IV Rated mains voltage ≤ 150 VRMS I – III ≤ 300 VRMS I– II ≤ 600 VRMS Capacitance input-to-output CIO –2 – pF – Resistance input-to-output RIO – >1000 – MΩ – Common Mode Transient Immunity CMTI 150 – – V/ns According to DIN V VDE V0884- 11, static and dynamic test Table 26 Reinforced isolation package characteristics (in WB PG-DSO-16-30) Parameter Symbol Values Unit Note or Test Condition Min. Typ. Max. Comparative Tracking Index of package mold CTI 400 – 600 V According to DIN EN 60112 (VDE 0303-11) Material group – – II – – According to IEC 60112 Pollution degree – – 2 – – – Climatic category – – 40/125/ 21 –– – |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |