| поискавой системы для электроныых деталей |
|
1908 датащи(PDF) 6 Page - Thurlby Thandar Instruments Ltd. |
|
|
|||||||||||||||||||||||||||||
1908 датащи(HTML) 6 Page - Thurlby Thandar Instruments Ltd. |
|
6 / 14 page ![]() * LabView and LabWindows are trademarks of National Instruments Keysight VEE is a trademark of Keysight Technologies. Windows is a trademark of Microsoft. ** GPIB optional DATA STORAGE A convenient front mounted flash drive port allows configurations, results and screen shots to be directly extracted from the instrument for further analysis. The direct upload of complex test configurations enables simplification of the of the most advanced test scenarios. Measurement data can be automatically recorded to the flash drive on completion of a test run – thus allowing for virtually unlimited measurement data storage. ADVANCED SEQUENCING MODE Sequence mode is an advanced sequencing feature for creating and performing complex test routines. Stored test configuration setups can be imported into up to 25 individual steps inside one test routine, allowing complete synchronisation of the instrument via advanced triggering capabilities and features. Synchronisation of two instruments or additional test equipment can be achieved through the use of the DIO port under the control of the sequence mode engine. SIMPLIFY TEST SETUPS ** SCPI COMPATIBLE The SMU can be integrated into existing systems using the universal SCPI command set. An extensive library of commands can be used to simplify setups and automate systems, increasing productivity and reducing costs. LABVIEW & IVI DRIVER An IVI-COM/IVI-C driver for Windows is included. This provides support for common high-level applications such as LabView*, LabWindows*, and Keysight VEE*. ACCESSORIES This instrument can be rack mounted, a suitable 2U 19” rack kit is available from the manufacturers or their overseas agents. Contact TTi for test fixture requirements. TRIGGER DELAY DIO OUT RUN STORED TEST SETUP CONDITION CONDITION CONDITION ACTION REPEAT NEXT STEP LEVEL: Monitor for a set level (V, A, W or Ω) including: <= or => than a set level, within two set levels or outside of two set levels. TIMEOUT: Run for a specified period of time (ms/s). EXTERNAL INPUT TRIGGER: Monitor for external triggers via remote command or DIO. Up to three conditions can be applied, the same condition can be used mulitple times. CONDITION OPTIONS JUMP TO STEP: Jump to a pre- defined step or next step in the sequence. DIO OUTPUT LEVEL: Set DIO output pin as Logic High (5V) or Logic Low (0V) STOP: Stop the sequence. Any action can be added to a condition, the same action can be used multiple times. ACTION FOR A MET CONDITION Wait for an external trigger via remote command or DIO EXTERNAL INPUT TRIGGER Set DIO output pin as Logic High (5V) or Logic Low (0V) DIO OUTPUT Repeat the step a defined number of times REPEAT ACTION ACTION EXAMPLE OF A SINGLE STEP INSIDE A SEQUENCED TEST ROUTINE |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |