| поискавой системы для электроныых деталей |
|
TMP451 датащи(PDF) 13 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMP451 датащи(HTML) 13 Page - Texas Instruments |
|
13 / 42 page ![]() Frame 1 Two-Wire Slave Address Byte Frame 2 Pointer Register Byte 1 Start By Master ACK By Device ACK By Device 1 9 1 Frame 3 Data Byte 1 ACK By Device 1 D7 SDA (Continued) SCL (Continued) D6 D5 D4 D3 D2 D1 D0 9 9 SDA SCL 0 0 1 1 0 0 (1) R/W P7 P6 P5 P4 P3 P2 P1 P0 ¼ ¼ Stop By Master TMP451 www.ti.com SBOS686A – JUNE 2013 – REVISED DECEMBER 2014 Programming (continued) 7.5.1.1 Bus Overview The TMP451 device is SMBus interface compatible. In SMBus protocol, the device that initiates the transfer is called a master, and the devices controlled by the master are slaves. The bus must be controlled by a master device that generates the serial clock (SCL), controls the bus access, and generates the START and STOP conditions. To address a specific device, a START condition is initiated. A START condition is indicated by pulling the data line (SDA) from a high-to-low logic level while SCL is high. All slaves on the bus shift in the slave address byte, with the last bit indicating whether a read or write operation is intended. During the ninth clock pulse, the slave being addressed responds to the master by generating an acknowledge bit and pulling SDA low. Data transfer is then initiated and sent over eight clock pulses followed by an acknowledge bit. During data transfer SDA must remain stable while SCL is high, because any change in SDA while SCL is high is interpreted as a control signal. After all data have been transferred, the master generates a STOP condition. A STOP condition is indicated by pulling SDA from low to high, while SCL is high. 7.5.1.2 Bus Definitions The TMP451 device is two-wire and SMBus-compatible. Figure 15 and Figure 16 show the timing for various operations on the TMP451 device. The bus definitions are as follows: Acknowledge: Each receiving device, when addressed, is obliged to generate an acknowledge bit. A device that acknowledges must pull down the SDA line during the acknowledge clock pulse in such a way that the SDA line is stable low during the high period of the acknowledge clock pulse. Take setup and hold times into account. On a master receive, data transfer termination can be signaled by the master generating a not-acknowledge on the last byte that has been transmitted by the slave. Bus Idle: Both SDA and SCL lines remain high. Data Transfer: The number of data bytes transferred between a START and a STOP condition is not limited and is determined by the master device. The receiver acknowledges data transfer. Start Data Transfer: A change in the state of the SDA line, from high to low, while the SCL line is high, defines a start condition. Each data transfer initiates with a START condition. Stop Data Transfer: A change in the state of the SDA line from low to high while the SCL line is high defines a STOP condition. Each data transfer terminates with a repeated START or STOP condition. (1) Slave address 1001100 shown. Figure 15. Two-Wire Timing Diagram for Write Word Format Copyright © 2013–2014, Texas Instruments Incorporated Submit Documentation Feedback 13 Product Folder Links: TMP451 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |