45 / 106 page ![]() DocID025743 Rev 6 45/106 STM32F031x4 STM32F031x6 Electrical characteristics 80 IDD Supply current in Sleep mode HSE bypass, PLL on 48 MHz 10.7 11.7(2) 11.9 12.5(2) 2.4 2.6(2) 2.7 2.9(2) mA 32 MHz 7.1 7.8 8.1 8.2 1.6 1.7 1.9 1.9 24 MHz 5.5 6.3 6.4 6.4 1.3 1.4 1.5 1.5 HSE bypass, PLL off 8 MHz 1.8 2.0 2.0 2.1 0.4 0.4 0.5 0.5 1 MHz 0.2 0.5 0.5 0.5 0.1 0.1 0.1 0.1 HSI clock, PLL on 48 MHz 10.8 11.9 12.1 12.6 2.4 2.7 2.7 2.9 32 MHz 7.3 8.0 8.4 8.5 1.7 1.9 1.9 2.0 24 MHz 5.5 6.2 6.5 6.5 1.3 1.5 1.5 1.6 HSI clock, PLL off 8 MHz 1.9 2.2 2.3 2.4 0.5 0.5 0.5 0.6 1. Data based on characterization results, not tested in production unless otherwise specified. 2. Data based on characterization results and tested in production (using one common test limit for sum of IDD and IDDA). Table 23. Typical and maximum current consumption from VDD at 3.6 V (continued) Symbol Parameter Conditions fHCLK All peripherals enabled All peripherals disabled Unit Typ Max @ TA(1) Typ Max @ TA(1) 25 °C 85 °C 105 °C 25 °C 85 °C 105 °C Table 24. Typical and maximum current consumption from the VDDA supply Symbol Parameter Conditions (1) fHCLK VDDA = 2.4 V VDDA = 3.6 V Unit Typ Max @ TA (2) Typ Max @ TA (2) 25 °C 85 °C 105 °C 25 °C 85 °C 105 °C IDDA Supply current in Run or Sleep mode, code executing from Flash memory or RAM HSE bypass, PLL on 48 MHz 150 170(3) 178 182(3) 164 183(3) 195 198(3) µA 32 MHz 104 121 126 128 113 129 135 138 24 MHz 82 96 100 103 88 102 106 108 HSE bypass, PLL off 8 MHz 2.0 2.7 3.1 3.3 3.5 3.8 4.1 4.4 1 MHz 2.0 2.7 3.1 3.3 3.5 3.8 4.1 4.4 HSI clock, PLL on 48 MHz 220 240 248 252 244 263 275 278 32 MHz 174 191 196 198 193 209 215 218 24 MHz 152 167 173 174 168 183 190 192 HSI clock, PLL off 8 MHz 72 79 82 83 83.5 91 94 95 1. Current consumption from the VDDA supply is independent of whether the digital peripherals are enabled or disabled, being in Run or Sleep mode or executing from Flash memory or RAM. Furthermore, when the PLL is off, IDDA is independent of clock frequencies. 2. Data based on characterization results, not tested in production unless otherwise specified. 3. Data based on characterization results and tested in production (using one common test limit for sum of IDD and IDDA). |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |