28 / 49 page ![]() Application information L9959 28/49 DocID027540 Rev 3 4.2.4 Short to battery (SCB) and short to Ground (SCG) While the power stages are on, the current through them is monitored. If the output current reaches the current limit IL, the output is switched off after the blanking time tb. In case the current reaches the limit IOC during this time, a short to battery (SCB) on low-sides or a short to ground (SCG) on high-sides is diagnosed, and the affected output driver is switched off immediately, the not affected one after the time tDF_del. In order to confirm this error, the outputs are turned on again. If the error is detected for the second time, it is confirmed but it is still not possible to determine to which of the following types belongs to: SCB and SCL SCG and SCL To discriminate the fault type, it is necessary to turn outputs on for the third time, and in case the fault is detected, the diagnosis register (DIA_REG1) is updated consequently and the device is disabled. Otherwise, the SCG and SCB faults are confirmed only. Figure 18. Current limiting and short circuit The three different over-current limits are related to the programmable current limitation, which can be programmed into the SPI register (Table 33: Configuration register (CONFIG_REG)). The over-current limits are independent of the resistor at pin CF. Note: SCG: Fault Detection works correctly if the following condition is respected: Duty (switch on time) > Tdon + Slew rate + tDF. 4.2.5 Short circuit over load (SCL) Short circuit over load (SCL) is diagnosed by a retest sequence after a short to battery (SCB) or a short to ground (SCG) has been detected and confirmed by a retry on the switched-on high-side and low-side driver. Then after the time tretest, the opposite driver is switched off (i.e. the high-side in case of a short to battery on the low-side and vice versa). If the failure then disappears, a short over load (SCL) is detected. The error is only entered into the diagnosis register and the device is disabled, if it is confirmed. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |