| поискавой системы для электроныых деталей |
|
PYF14ESSB датащи(PDF) 7 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
PYF14ESSB датащи(HTML) 7 Page - Omron Electronics LLC |
|
7 / 31 page ![]() 7 Products Related to Common Sockets and DIN Tracks Specifications Socket Characteristics Model Continuous carry current Dielectric strength Insulation resistance*1 Remarks P2RF-05(-E)(-S) 10 A Between contact terminals of same polarity: 1,000 VAC for 1 min 1,000 M Ω min. Between coil and contact terminals: 4,000 VAC for 1 min P2RF-08(-E)(-S) 5 A Between contact terminals of different polarity: 3,000 VAC for 1 min 1,000 M Ω min. Between contact terminals of same polarity: 1,000 VAC for 1 min Between coil and contact terminals: 4,000 VAC for 1 min P2R-05P 10 A Between contact terminals of same polarity: 1,000 VAC for 1 min 1,000 M Ω min. Between coil and contact terminals: 4,000 VAC for 1 min P2R-08P 5 A Between contact terminals of different polarity: 3,000 VAC for 1 min 1,000 M Ω min. Between contact terminals of same polarity: 1,000 VAC for 1 min Between coil and contact terminals: 4,000 VAC for 1 min P2R-057P 10 A Between contact terminals of same polarity: 1,000 VAC for 1 min 1,000 M Ω min. Between coil and contact terminals: 5,000 VAC for 1 min P2R-087P 5 A Between contact terminals of different polarity: 3,000 VAC for 1 min 1,000 M Ω min. Between contact terminals of same polarity: 1,000 VAC for 1 min Between coil and contact terminals: 5,000 VAC for 1 min P2R-05A 10 A Between contact terminals of same polarity: 1,000 VAC for 1 min 1,000 M Ω min. Between ground terminals: 1,500 VAC for 1 min Between coil and contact terminals: 4,000 VAC for 1 min P2R-08A 5 A Between contact terminals of different polarity: 3,000 VAC for 1 min 1,000 M Ω min. Between contact terminals of same polarity: 1,000 VAC for 1 min Between ground terminals: 1,500 VAC for 1 min Between coil and contact terminals: 4,000 VAC for 1 min P7TF-05 5 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. PYF08A(-E)(-S) 7 A, -S models: 10 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. The continuous carry current of 10 A for the PYF08S is for an ambient temperature of 55°C. At an ambient temperature of 70°C, the value is 7 A. PYF11A 5 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. PYF14A(-E)(-S) 3 A, -S models: 5 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. PY08(-Y1) 7 A Between terminals: 1,500 VAC for 1 min 1,000 M Ω min. PY08QN(-Y1) 7 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY08-02 7 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY11(-Y1) 5 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY11QN(-Y1) 5 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY11-02 5 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY14(-Y1) 3 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY14QN(-Y1) 3 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY14-02 3 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PTF @@A(-E) 10 A Between terminals: 2,000 VAC for 1 min 100 M Ω min. PT @@ 10 A Between terminals: 2,000 VAC for 1 min 100 M Ω min. PT @@QN 10 A Between terminals: 2,000 VAC for 1 min 100 M Ω min. PT @@-0 10 A Between terminals: 2,000 VAC for 1 min 100 M Ω min. P7LF-06 30 A Between contact terminals of different polarity: 2,000 VAC for 1 min 1,000 M Ω min. Between contact terminals of same polarity: 2,000 VAC for 1 min Between coil and contact terminals: 4,000 VAC for 1 min PF @@@A 5 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. P2CF 5 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. P3G(A) 6 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. 8PFA(1) 10 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. 11PFA(1) 10 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. PL @(-Q) 10 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. PLE @@-0 10 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. P6D-04P 5 A Between contact terminals of same polarity: 1,000 VAC for 1 min 100 M Ω min. Between coil and contact terminals: 3,000 VAC for 1 min P7S-14 @-E(ND) 10 A Between contact terminals of different polarity: 2,000 VAC for 1 min 1,000 M Ω min. Between contact terminals of same polarity: 1,500 VAC for 1 min Between coil and contact terminals: 2,000 VAC for 1 min |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |