| поискавой системы для электроныых деталей |
|
WM8994ECS/R датащи(PDF) 345 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
WM8994ECS/R датащи(HTML) 345 Page - Cirrus Logic |
|
345 / 363 page ![]() WM8994 Rev 4.6 345 REGISTER ADDRESS BIT LABEL DEFAULT DESCRIPTION REFER TO 5 FLL1_LOCK_EI NT 0 FLL1 Lock Interrupt (Rising and falling edge triggered) Note: Cleared when a ‘1’ is written. 4 MIC2_SHRT_EI NT 0 MICBIAS2 Short Circuit Interrupt (Rising and falling edge triggered) Note: Cleared when a ‘1’ is written. 3 MIC2_DET_EIN T 0 MICBIAS2 Current Detect Interrupt (Rising and falling edge triggered) Note: Cleared when a ‘1’ is written. 2 MIC1_SHRT_EI NT 0 MICBIAS1 Short Circuit Interrupt (Rising and falling edge triggered) Note: Cleared when a ‘1’ is written. 1 MIC1_DET_EIN T 0 MICBIAS1 Current Detect Interrupt (Rising and falling edge triggered) Note: Cleared when a ‘1’ is written. 0 TEMP_SHUT_E INT 0 Temperature Shutdown Interrupt (Rising and falling edge triggered) Note: Cleared when a ‘1’ is written. Register 0731h Interrupt Status 2 REGISTER ADDRESS BIT LABEL DEFAULT DESCRIPTION REFER TO R1842 (0732h) Interrupt Raw Status 2 15 TEMP_WARN_ STS 0 Temperature Warning status 0 = Temperature is below warning level 1 = Temperature is above warning level 14 DCS_DONE_ST S 0 DC Servo status 0 = DC Servo not complete 1 = DC Servo complete 13 WSEQ_DONE_ STS 0 Write Sequencer status 0 = Sequencer Busy (sequence in progress) 1 = Sequencer Idle 12 FIFOS_ERR_ST S 0 Digital Core FIFO Error status 0 = Normal operation 1 = FIFO Error 11 AIF2DRC_SIG_ DET_STS 0 AIF2 DRC Signal Detect status 0 = Signal threshold not exceeded 1 = Signal threshold exceeded 10 AIF1DRC2_SIG _DET_STS 0 AIF1 DRC2 (Timeslot 1) Signal Detect status 0 = Signal threshold not exceeded 1 = Signal threshold exceeded 9 AIF1DRC1_SIG _DET_STS 0 AIF1 DRC1 (Timeslot 0) Signal Detect status 0 = Signal threshold not exceeded 1 = Signal threshold exceeded 8 SRC2_LOCK_S TS 0 SRC2 Lock status 0 = Not locked 1 = Locked 7 SRC1_LOCK_S TS 0 SRC1 Lock status 0 = Not locked 1 = Locked 6 FLL2_LOCK_ST S 0 FLL2 Lock status 0 = Not locked |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |