3 / 13 page ![]() RFSW6024 5 MHz to 6 GHz Absorptive High Isolation SPDT Switch Datasheet, Rev. J, April 21, 2023 | Subject to change without notice 3 of 13 www.qorvo.com ® Electrical Specifications (Continued) Parameter Conditions (1) Min Typ Max Units Operational Frequency Range 5 6000 MHz Input IP3 1.0 GHz +12 dBm input power per-tone, 1 MHz tone spacing 55 65 dBm 2.0 GHz 55 65 dBm Input 0.1 dB Compression Power 1.0 GHz 36 dBm Input 1 dB Compression Power 1.0 GHz 36 dBm Setting Time 50% VCTL to optimum functionality 1.5 3.0 μs Start-up Time 90% VDD to full functionality 25 50 μs Switching Time 50% control to 10/90% RF 250 ns 50% control to 2/98% RF 360 600 ns Supply Current (IDD) VDD 5.0V 140 200 μA Control Current, (ICTL, IEN) VCTL 5.0V 0.5 5.0 μA Low Control Voltage (VCTL) 1.8 V Logic compatible 0 0.63 V High Control Voltage (VCTL) 1.1 VDD V Notes: 1. Test conditions unless otherwise noted: VDD = +5.0 V, VCTL = 0/+5.0 V, Temp = +25 °C, 50 Ω system, RF ports DC Voltage 0V 2. PCB trace loss deducted. Maximum Operating Power at +85C, ≥300 MHz CW Input Port State VEN Power Thermal Resistance, θjc RFC, RF1 or RF2 ON Low 33.0 dBm (1) 97 °C/W (2) RFC Both OFF & RFC Reflective High 31.3 dBm N/A RF1 or RF2 OFF & Terminated (5) Low or High 26.0 dBm 100 °C/W RF1 and RF2 Both OFF & Terminated (5) High 27.8 dBm (3) 65 °C/W Notes: 1. Load VSWR ≤ 3:1; for higher load VSWR, the maximum Input power reduced to +30.5 dBm 2. Apply to resistive loss from the insertion loss not including mismatch loss 3. Total power on both RF1 and RF2 ports being driven simultaneously 4. For < 300 MHz, it is recommended to operate at least 4 dB below Input 1 dB Compression Power 5. Internally terminated Truth Table Control Input Signal Path State VCTL VEN RFC ⇆ RF1 RFC ⇆ RF2 0 0 OFF ON 1 0 ON OFF 0 1 OFF OFF 1 1 OFF OFF Notes: “0” = 0 V to 0.63 V; “1” = 1.1 V to VDD; VDD = 2.5 to 5.5 V must be applied for all valid states |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |