| поискавой системы для электроныых деталей |
|
BME280 датащи(PDF) 14 Page - Bosch Sensortec GmbH |
|
|
|||||||||||||||||||||||||||||
BME280 датащи(HTML) 14 Page - Bosch Sensortec GmbH |
|
14 / 60 page ![]() Bosch Sensortec | BME280 Data sheet 14 | 60 Modifications reserved | Data subject to change without notice Document number: BST-BME280-DS001-23 Revision_1.23_012022 3. Functional description 3.1 Block diagram Figure 2 shows a simplified block diagram of the BME280: Logic Pressure front-end OSC NVM Voltage reference Voltage regulator (analog & digital) VDDIO GND I n t e r f a c e SDI SDO SCK CSB VDD POR Pressure sensing element Humidity sensing element Humidity front-end Temperature front-end Temperature sensing element ADC Figure 2: Block diagram of BME280 3.2 Power management The BME280 has two distinct power supply pins • VDD is the main power supply for all internal analog and digital functional blocks • VDDIO is a separate power supply pin used for the supply of the digital interface A power-on reset (POR) generator is built in; it resets the logic part and the register values after both VDD and VDDIO reach their minimum levels. There are no limitations on slope and sequence of raising the VDD and VDDIO levels. After powering up, the sensor settles in sleep mode (described in chapter 3.3.2). It is prohibited to keep any interface pin (SDI, SDO, SCK or CSB) at a logical high level when VDDIO is switched off. Such a configuration can permanently damage the device due an excessive current flow through the ESD protection diodes. If VDDIO is supplied, but VDD is not, the interface pins are kept at a high-Z level. The bus can therefore already be used freely before the BME280 VDD supply is established. Resetting the sensor is possible by cycling VDD level or by writing a soft reset command. Cycling the VDDIO level will not cause a reset. 3.3 Sensor modes The BME280 offers three sensor modes: sleep mode, forced mode and normal mode. These can be selected using the mode[1:0] setting (see chapter 5.4.5). The available modes are: • Sleep mode: no operation, all registers accessible, lowest power, selected after startup • Forced mode: perform one measurement, store results and return to sleep mode • Normal mode: perpetual cycling of measurements and inactive periods. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |