| поискавой системы для электроныых деталей |
|
AV45C датащи(PDF) 18 Page - Astec America, Inc |
|
|
|||||||||||||||||||||||||||||
AV45C датащи(HTML) 18 Page - Astec America, Inc |
|
18 / 25 page ![]() A A A AV V V V 4 4 4 4 5 5 5 5 C C C C Q Q Q Q u u u u a a a a rrrrtttte e e e rrrr--B B B B rrrriiiic c c c k k k k S S S S e e e e rrrriiiie e e e s s s s 1 1 1 1 0 0 0 0 0 0 0 0 W W W W P P P P o o o o w w w w e e e e rrrr C C C C o o o o n n n n v v v v e e e e rrrrtttte e e e rrrrs s s s 3 3 3 3 6 6 6 6 V V V V d d d d c c c c tttto o o o 7 7 7 7 5 5 5 5 V V V V d d d d c c c c IIIIn n n n p p p p u u u u tttt,,,, S S S S iiiin n n n g g g g lllle e e e O O O O u u u u ttttp p p p u u u u tttt -18- USA Europe Asia TEL: 1-760-930-4600 44-(0)1384-842-211 852-2437-9662 FAX: 1-760-930-0698 44-(0)1384-843-355 852-2402-4426 www.astec.com module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standard, i.e., UL1950, CSA C22.2 No. 950-95, and EN60950. The input-to-output 1500VDC isolation is an opera- tional insulation. The DC/DC power module should be installed in end-use equipment, in compliance with the requirements of the ulti- mate application, and is intended to be supplied by an isolated secondary circuit. When the sup- ply to the DC/DC power module meets all the requirements for SELV(<60Vdc), the output is considered to remain within SELV limits (level 3). If connected to a 60Vdc power system, dou- ble or reinforced insulation must be provided in the power supply that isolates the input from any hazardous voltages, including the ac mains. One input pin and one output pin are to be grounded or both the input and output pins are to be kept floating. Single fault testing in the power supply must be performed in combi- nation with the DC/DC power module to demonstrate that the output meets the require- ment for SELV. The input pins of the module are not operator accessible. Note: Do not ground either of the input pins of the module, without grounding one of the output pins. This may allow a non-SELV voltage to appear between the output pin and ground. Output Characteristics Output Characteristics Minimum Load Requirement Minimum Load Requirement There is no minimum load requirement for the AV45C quarter-brick series modules. Remote Sensing Remote Sensing The AV45C quarter-brick series can remotely sense both lines of its output which moves the effective output voltage regulation point from the output terminals of the unit to the point of connection of the remote sense pins. This fea- ture automatically adjusts the real output volt- age of the AV45C series in order to compen- sate for voltage drops in distribution and main- tain a regulated voltage at the point of load. When the converter is supporting loads far away, or is used with undersized cabling, sig- nificant voltage drop can occur at the load. The best defense against such drops is to locate the load close to the converter and to ensure ade- quately sized cabling is used. When this is not possible, the converter can compensate for a drop of up to 10%Vo, through use of the sense leads. When used, the + and - Sense leads should be connected from the converter to the point of load as shown in Figure 9 using twisted pair wire. The converter will then regulate its output voltage at the point where the leads are con- nected. Care should be taken not to reverse the sense leads. If reversed, the converter will trig- ger OVP protection and turn off. When not used, the +Sense lead must be connected with +Vo, and -Sense with -Vo. Also note that the output voltage and the remote sense voltage offset must be less than the minimum overvolt- age trip point. Note that at elevated output voltages the maxi- mum power rating of the module remains the same, and the output current capability will decrease correspondingly. +Vout -Vout Load +Sense -Sense Twisted Pair +S -S Fig.9 Sense Connections |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |