27 / 292 page ![]() Power DSP56303 User’s Manual, Rev. 2 Freescale Semiconductor 2-3 2.1 Power 2.2 Ground Table 2-2. Power Inputs Power Name Description VCCP PLL Power VCC dedicated for use with Phase Lock Loop (PLL). The voltage should be well-regulated and the input should be provided with an extremely low impedance path to the VCC power rail. VCCQ (4) Quiet Power An isolated power for the internal processing logic. This input must be tied externally to all other chip power inputs, except for VCCP. The user must provide adequate external decoupling capacitors. VCCA (4) Address Bus Power An isolated power for sections of the address bus I/O drivers. This input must be tied externally to all other chip power inputs, except for VCCP. The user must provide adequate external decoupling capacitors. VCCD (4) Data Bus Power An isolated power for sections of the data bus I/O drivers. This input must be tied externally to all other chip power inputs, except for VCCP. The user must provide adequate external decoupling capacitors. VCCC (2) Bus Control Power An isolated power for the bus control I/O drivers. This input must be tied externally to all other chip power inputs, except for VCCP. The user must provide adequate external decoupling capacitors. VCCH Host Power An isolated power for the HI08 I/O drivers. This input must be tied externally to all other chip power inputs, except for VCCP. The user must provide adequate external decoupling capacitors. VCCS (2) ESSI, SCI, and Timer Power An isolated power for the ESSI, SCI, and timer I/O drivers. This input must be tied externally to all other chip power inputs, except for VCCP. The user must provide adequate external decoupling capacitors. Note: These designations are package-dependent. Some packages connect all VCC inputs except VCCP to each other internally. On those packages, all power input except VCCP are labeled VCC. The numbers of connections indicated in this table are minimum values; the total VCC connections are package-dependent. Table 2-3. Grounds Ground Name Description GNDP PLL Ground Ground dedicated for PLL use. The connection should be provided with an extremely low-impedance path to ground. VCCP should be bypassed to GNDP by a 0.47 µF capacitor located as close as possible to the chip package. GNDP1 PLL Ground 1 Ground dedicated for PLL use. The connection should be provided with an extremely low-impedance path to ground. GNDQ (4) Quiet Ground An isolated ground for the internal processing logic. This connection must be tied externally to all other chip ground connections, except GNDP and GNDP1. The user must provide adequate external decoupling capacitors. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |