| поискавой системы для электроныых деталей |
|
HT82K94E датащи(PDF) 19 Page - Holtek Semiconductor Inc |
|
|
|||||||||||||||||||||||||||||
HT82K94E датащи(HTML) 19 Page - Holtek Semiconductor Inc |
|
19 / 43 page ![]() HT82K94E/HT82K94A Rev. 1.50 19 October 11, 2007 STALL, PIPE, PIPE_CTRL and Endpt_EN Registers PIPE register represents whether the endpoint corresponding is accessed by host or not. After ACT_EN signal being sent out, MCU can check which endpoint had been accessed. This register is set only after the time when host access the corresponding endpoint. STALL register shows whether the endpoint corresponding works or not. As soon as the endpoint work improperly, the bit corresponding must be set. PIPE_CTRL Register is used for configuring IN (Bit=1) or OUT (Bit=0)Pipe. The default is define IN pipe. Where Bit0 (DATA0) of the PIPE_CTRL Register is used to setting the data toggle of any endpoint (except endpoint0) using data toggles to the value DATA0. Once the user want the any endpoint (except endpoint0) using data toggles to the value DATA0. the user can output a LOW pulse to this bit. The LOW pulse period must at least 10 instruction cycle. Endpt_EN Register is used to enable or disable the corresponding endpoint (except endpoint 0) Enable Endpoint (Bit=1) or disable Endpoint (Bit=0) The bitmaps are list as follows : Register Name R/W Register Address Bit7~Bit4 Reserved Bit 3 Bit 2 Bit 1 Bit 0 Default Value PIPE_CTRL R/W 01000001B ¾ Pipe 3 Pipe 2 Pipe 1 Pipe 0 00001111 STALL R/W 01000011B ¾ Pipe 3 Pipe 2 Pipe 1 Pipe 0 00001111 PIPE R 01000100B ¾ Pipe 3 Pipe 2 Pipe 1 Pipe 0 00000000 Endpt_EN R/W 01000001B ¾ Pipe 3 Pipe 2 Pipe 1 Pipe 0 00001111 PIPE_CTRL (41H), STALL (43H), PIPE (44H) and Endpt_EN (47H) Registers The SIES Register is used to indicate the present signal state which the SIE receives and also defines whether the SIE has to change the device address automatically. Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 Func. NMI EOT CRC_ERR NAK IN OUT F0_ERR Adr_set R/W R/W R R/W R R R/W R/W R/W Reg_ Adr 01000101B SIES (45H) Register Func. Name R/W Description Adr_ set R/W This bit is used to configure the SIE to automatically change the device address with the value of the Address+Remote_WakeUp Register (42H). When this bit is set to ²1² by F/W, the SIE will update the device address with the value of the Address+Remote_WakeUp Register (42H) after the PC Host has successfully read the data from the device by the IN operation. The SIE will clear the bit after updat- ing the device address. Otherwise, when this bit is cleared to ²0², the SIE will update the device address immediately after an address is written to the Address+Re- mote_WakeUp Register (42H) Default 0 F0_Err R/W This bit is used to indicate that some errors have occurred when accessing the FIFO0. This bit is set by SIE and cleared by F/W. Default 0 Out R/W This bit is used to indicate that an OUT token (except for the OUT zero length) has been received. The F/W clear the bit after the OUT data has been read. This bit will also be cleared by the SIE after the next valid SETUP token is received. Default 0 IN R This bit is used to indicate that the current signal the USB is receiving from the PC Host is IN token. NAK R This bit is used to indicate that the SIE is transmitting NAK signal to the Host in re- sponse to the PC Host IN or OUT token. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |