| поискавой системы для электроныых деталей |
|
SC905AEVB датащи(PDF) 11 Page - Semtech Corporation |
|
|
|||||||||||||||||||||||||||||
SC905AEVB датащи(HTML) 11 Page - Semtech Corporation |
|
11 / 23 page ![]() 11 © 2006 Semtech Corp. www.semtech.com POWER MANAGEMENT SC905A means that these LDOs are on when there is a ‘1’ in their respective bit locations (register 6, bit 3 for VTCXO, register 2, bit 6 for VMOT), or if their external enable pins are pulled HIGH. To turn these LDOs off the I2C on/off control bit must be ‘0’ and the external enable must be pulled LOW. The state of EN_TCXO and EN_MOT can be established by reading bits 0 and 2, respectively, in the Status Register. VCSEL & VPSEL Pin The VCSEL & VPSEL pins set the default voltage of CORE and PAD LDOs respectively. When the VCSEL pin is set to VIN the default voltage for the CORE LDO is 1.80V. When this pin is set to GND the default voltage for the CORE LDO is 1.35V. Likewise, when the VPSEL pin is set to VIN the default voltage for the PAD LDO is 3.00V. When this pin is set to GND, the default voltage for the PAD LDO is 2.20V. In both cases the VCSEL and VPSEL pins must be tied to GND or VIN prior to the device being powered on. This voltage cannot change on the fly by switching the pin voltage between VIN or GND once the device is on. The voltage can be changed from its default state after start-up by writing to the appropriate voltage code register. Active Shutdown The shutdown control bits determine how the on-chip active shutdown switches behave. Register 7 is the active shutdown control register and is used to control the shutdown behavior. Each LDO has a specific shutdown bit assigned to it. When the active shutdown bit is enabled (set to 1), the output capacitance on the LDO output is discharged by an on-chip FET when the LDO is disabled. When the active shutdown bit is disabled (set to 0), the output capacitance on the LDO output is discharged by the load. The default state for each LDO active shutdown bit is on. Default Status Bit In many multi-threaded environments it is necessary to maintain synchronization between the host micro-controller and the target IC. The SC905A has a default status bit (DSB) that will facilitate this task. The DSB can be useful in keeping the MSM and the SC905A synchronized. However, this is only useful if the MSM is powered by an external switching regulator such as Semtech’s SC190A switching regulator. The DSB is bit 7 of register 0, and shares this register space with the PAD voltage control bits. The DSB is only set to 1 during power-up to indicate that the part is set to the default state. Moreover, the DSB cannot be written to a 1 through the I2C interface the way the other bits in this register can; it can only be cleared to 0 through the I2C interface. This feature prevents a software race condition by always writing to register 0 with bit 7 high when changing the PAD control voltage. To clear the bit simply write a 0 to bit 7. Applying the DSB Upon power-up, the SC905A LDOs and internal registers are set to their default state. The DSB is set to a 1 to indicate that the SC905A is in its default state. Upon reading this defaulted state condition, the MSM knows to perform whatever synchronization is needed to set the SC905A into a known user state. This user state is entered by a two-stage process. 1) The MSM writes a 0 to the DSB indicating its desire to modify the state of the SC905A. It then writes all of the correct register information to the SC905A to set it to the user state. 2) The MSM reads back all of the information to verify the data. Then it reads back the DSB again to ensure it is still set to 0. This verifies that no reset took place during the time that the multiple writes and read verifications happened. If the DSB has been reset to 1, this process needs to be repeated since the chip was reset sometime during the initialization. Once the MSM and the SC905A are synchronized, the DSB can be read back as a status check periodically, as needed. If it is ever set back to the default state, a new synchronization process is required. This handshake-style protocol makes sure that the MSM and SC905A are always synchronized. LDO Power-On Sequence When the SC905A first turns on, the four LDOs that default on are sequenced in the following fashion: 1) CORE, 2) PAD, 3) ANA, 4) TCXO. During the power-on sequence, there is a 200μs delay between CORE and PAD to allow the output of CORE to reach 1.2V before PAD is turned on, a delay of 100μs between PAD and ANA turning on, and a delay of 100μs between ANA and TCXO turning on. This process eliminates large voltage spikes across the battery supply during power-up. (For further information on LDO power on sequencing, refer to the Timing Diagram on page 19.) Applications Information (Cont.) |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |