| поискавой системы для электроныых деталей |
|
SC905 датащи(PDF) 11 Page - Semtech Corporation |
|
|
|||||||||||||||||||||||||||||
SC905 датащи(HTML) 11 Page - Semtech Corporation |
|
11 / 21 page ![]() 11 © 2006 Semtech Corp. www.semtech.com POWER MANAGEMENT SC905 The voltage can be changed from its default state after start-up by writing to the appropriate voltage code regis- ter. Active Shutdown The shutdown control bits determine how the on-chip active shutdown switches behave. Register 7 is the active shut- down control register and is used to control the shutdown behavior. Each LDO has a specific shutdown bit assigned to it. When the active shutdown bit is enabled (set to 1), the output capacitance on the LDO output is discharged by an on-chip FET when the LDO is disabled. When the active shutdown bit is disabled (set to 0), the output capacitance on the LDO output is discharged by the load. The default state for each LDO active shutdown bit is on. Default Status Bit In many multi-threaded environments it is necessary to maintain synchronization between the host micro-control- ler and the target IC. The SC905 has a default status bit (DSB) that will facilitate this task. The DSB can be useful in keeping the MSM and the SC905 synchronized. However, this is only useful if the MSM is powered by an external switching regulator such as the SC190. The DSB is bit 7 of register 0, and shares this register space with the PAD voltage control bits. The DSB is only set to 1 during power-up to indicate that the part is set to the default state. Moreover, the DSB cannot be written to a 1 through the I2C interface the way the other bits in this register can; it can only be cleared to 0 through the I2C interface. This feature prevents a software race condition by always writing to register 0 with bit 7 high when changing the PAD control voltage. To clear the bit simply write a 0 to bit 7. Applying the DSB Upon power-up, the SC905 LDOs and internal registers are set to their default state. The DSB is set to a 1 to indicate that the SC905 is in its default state. Upon reading this defaulted state condition, the MSM knows to perform whatever synchronization is needed to set the SC905 into a known user state. This user state is entered by a two- stage process. 1) The MSM writes a 0 to the DSB indicating its desire to modify the state of the SC905. It then writes all of the correct register information to the SC905 to set it to the user state. 2) The MSM reads back all of the information to verify the data. Then it reads back the DSB again to ensure it is still set to 0. This verifies that no reset took place during the time that the multiple writes and read verifications happened. If the DSB has been reset to 1, this process needs to be repeated since the chip was reset sometime during the initialization. Once the MSM and the SC905 are synchronized, the DSB can be read back as a status check periodically, as needed. If it is ever set back to the default state, a new synchronization process is required. This handshake-style protocol makes sure that the MSM and SC905 are always synchronized. LDO Power-On Sequence When the SC905 first turns on, the four LDOs that default on are sequenced in the following fashion: CORE is the first to turn on, then PAD, then ANA and finally TCXO. During the power-on sequence, each LDO has a 100μs delay from one LDO turning on to the other. This process eliminates large voltage spikes across the battery supply during power-up. For further information on LDO power on sequencing, refer to the Timing Diagram on page 17. Protection Circuitry The SC905 contains protection circuitry that prevents the device from operating in an unspecified state. These in- clude Under-voltage Lockout Protection, Over-temperature Protection and Short-circuit Protection. Under-Voltage Lockout The SC905 provides an under-voltage lockout (UVLO) circuit to protect the device from operating in an unknown state if the input voltage supply is too low. When the battery voltage drops below the UVLO threshold, as defined in the Electrical Characteristics section, the LDOs are disabled and RESB is held low. When the battery voltage is increased above the hysteresis level, the LDOs are re-enabled into their previous states, provided PGOOD has remained high. If PGOOD goes low, the SC905 will shut down. When powering-up with a battery voltage below the UVLO threshold, RESB will be held low. Applications Information (Cont.) |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |