| поискавой системы для электроныых деталей |
|
IXLDP датащи(PDF) 2 Page - Ashcroft, Inc. |
|
|
|||||||||||||||||||||||||||||
IXLDP датащи(HTML) 2 Page - Ashcroft, Inc. |
|
2 / 4 page ![]() of 4 2 IXLdp Ultra-Low Differential Pressure Transducer Data Sheet All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Si-Glas™, TruAccuracy™, Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: Lexan®. For more information, see Ashcroft Brands & Trademarks ©2022 Ashcroft Inc. IXLdp_transducer_ds_RevC_10-24-22 ashcroft.com | 1.800.328.8258 | Contact Us Output Signal: 4-20 mA (2-wire) 12-36 Vdc 0-5 Vdc (3-wire) 12-36 Vdc 1-5 Vdc (3-wire) 12-36 Vdc 1-6 Vdc (3-wire) 12-36 Vdc ±2.5 Vdc (3-wire) 12-36 Vdc ±5 Vdc (3-wire) 12-36 Vdc Output signal is independent of power supply changes: 12-36 Vdc range without effect on output signal PHYSICAL SPECIFICATIONS Electrical Connection: 1/2˝ Female electrical conduit connections isolated from the electronics. Separate access cover for terminal connections Environmental Rating: NEMA 4X Process Connection: 1/4 NPT Female HAZARDOUS SPECIFICATIONS FM (OPT.) Approval: Intrinsically Safe: Class I, II, III Div. 1 Groups A, B, C, D, E, F and G when properly installed with an approved FM intrinsically safe barrier. Non-incendive: Class I, II and III Div. 2, Groups A, B, C, D, E, F and G (4-20 mA output only) The output signal is limited to 12-30 Vdc for FM version units. Consult Factory for: Other pressure range,temperature compensation, packaging variations or response times WETTED MATERIAL Media: Clean, dry air/gases compatible with Aluminum, Titanium, PBT, Buna, Silicon, Glass, Gold, Silicone RTV and Stainless steel NOT FOR USE WITH LIQUIDS NON-WETTED Housing: 300 Series stainless steel Ashcroft’s TruAccuracy™ specification is exclusively based on terminal point methodology instead of statistically derived schemes like ‘best fit straight line’. TruAccuracy™ means the Ashcroft IXLdp has ±0.25% of span accuracy out of the box. Zero and span setting errors are already included in the ±0.25% of span accuracy spec. The IXLdp is ready to be installed with no additional calibration adjustments required. A unit from another manufacturer advertised as ±0.25% best fit straight line may actually be a ±1.25% to ±2.25% device. Using best fit straight line method, the accuracy spec does not include zero and span setting errors, which can be as much as ±1.00% each. What Does It Mean? Featuring a highly reliable variable capacitance sensor using the patented Ashcroft® Si-Glas™ sensor. This ultra-thin single crystal diaphragm provides inherent sensor repeatability and stability. SENSOR CROSS SECTION Ashcroft® Si-Glas™ Sensor Technology Sensor Cross Section The silicon diaphragm sensor has no glues or other organics to contribute to drift or mechanical degradation over time. LOAD LIMITATIONS 4-20 mA OUTPUT ONLY Loop Suppl y Voltage (Vdc) 0 10 12 20 24 30 36 40 0 250 500 750 1,000 1,250 1,091 OPERATING REGION 545 V min = 12V+ (0.022A x RL) R L = R S + RW R L = Loop Resistance (ohms) R S = Sense Resistance (ohms) R W = Wire Resistance (ohms) |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |