| поискавой системы для электроныых деталей |
|
IXLDP датащи(PDF) 1 Page - Ashcroft, Inc. |
|
|
|||||||||||||||||||||||||||||
IXLDP датащи(HTML) 1 Page - Ashcroft, Inc. |
|
1 / 4 page ![]() of 4 1 IXLdp Ultra-Low Differential Pressure Transducer Data Sheet All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Si-Glas™, TruAccuracy™, Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: Lexan®. For more information, see Ashcroft Brands & Trademarks ©2022 Ashcroft Inc. IXLdp_transducer_ds_RevC_10-24-22 ashcroft.com | 1.800.328.8258 | Contact Us FEATURES TruAccuracy™- Terminal Point Accuracy method includes non-linearity, hysteresis, non-repeatability, zero offset and span setting errors. Current and voltage output signals available Custom ranges available FM approval for hazardous locations (optional) 5:1 turndown option Si-Glas™ sensor technology enables precise measurement and control of very low pressures TYPICAL USES HVAC/R Fume hood control Lab/clean/hospital room pressurization Laminar flow Furnace/stack draft Leak detection Pollution/filtering monitoring Medical equipment Fan tracking Filter monitoring Velocity measurements Building energy management/comfort control systems KEY BENEFITS • Broad temperature capability • Superior long-term stability and repeatability • High overpressure protection • On-board voltage regulation allows use of lower cost, unregulated power supply • 3 year warranty PERFORMANCE SPECIFICATIONS Reference Temperature: 70 °F ±2 °F (21 °C ±1 °F) Accuracy: ±0.25% of span, ±0.5% of span ( Terminal Point Method: includes non-linearity, hysteresis, non- repeatability, zero offset and span setting errors) Stability: ±0.25% of span/year at reference conditions Media Compatibility: Clean, dry and non-corrosive gas NOT FOR USE WITH LIQUIDS Standard Response Time: 250 ms ENVIRONMENTAL SPECIFICATIONS Temperature Limits: Storage: Operating: Operating (FM): Compensated: -40 °F to 210 °F (-40 °C to 99 °C) -20 °F to 185 °F (-29 °C to 85 °C) -4 °F to 104 °F (-20 °C to 40 °C) 0 °F to 160 °F (-18 °C to 7 °C) Thermal Coefficients 0.25% Accuracy: Zero: ±0.01% of span/°F Span: ±0.01% of span/°F Thermal Coefficients 0.5% Accuracy: Zero: ±0.02% of span/°F Span: ±0.02% of span/°F Vibration Sweep: <0.2% span/g temporary effect 10-130 Hz Humidity Effects: No performance effect at 0-95% R.H. noncondensing FUNCTIONAL SPECIFICATIONS Mounting Position Effect: ≥1 in H2O: ±0.1% of span/g 0.25 in H2O to 0.5 in H2O: ±0.5% of span/g 0.1 in H2O: ±0.8% of span/g Calibrated horizontally standard unless otherwise specified. Mounting position effect easily corrected with zero potentiometer Max. Static (Line) Pressure: 100 psi Proof: 20 psid Burst: 50 psid ELECTRICAL SPECIFICATIONS Circuit Protection: Reverse wiring protected Potentiometers: Internal Zero: ±10% of span Span: ±10% of span Supply Current: 2.6 mA typical for Voltage output Warm-up Time: <1 second IXLdp Pressure Transducer |
Аналогичный номер детали - IXLDP |
|
Аналогичное описание - IXLDP |
|
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |