| поискавой системы для электроныых деталей |
|
CS44600 датащи(PDF) 52 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS44600 датащи(HTML) 52 Page - Cirrus Logic |
|
52 / 76 page ![]() 52 DS633F1 CS44600 7.5.4 De-Emphasis Control (DEM[1:0]) Default = 00 00 - no de-emphasis 01 - 32 kHz de-emphasis filter 10 - 44.1 kHz de-emphasis filter 11 - 48 kHz de-emphasis filter Function: Enables the appropriate digital filter to maintain the standard 15 ms/50 ms digital de-emphasis filter re- sponse. 7.6 Ramp Configuration (address 05h) 7.6.1 Ramp-Up/Down Setting (RAMP[1:0]) Default = 00 00 - Ramp-up and ramp-down are disabled 01 - Ramp-up is disabled. Ramp-down is enabled. 10 - Reserved 11 - Ramp-up and ramp-down are enabled. Note that after a ramp-up sequence has completed, audio will not play until RAMP[1:0] is set to 01. Function: When ramping is enabled, the duty cycle of the output PWM signal is increased (ramp-up) or decreased (ramp-down) at a rate determined by the Ramp Speed variable (RAMP_SPDx). This function is used in single-ended applications to reduce pops in the output caused by the DC-blocking capacitor. When the ramp-up/down function is disabled in single-ended applications, there will be an abrupt change in the out- put signal. Refer to Section 5.1.1 . If ramp-up or down is not needed, as in a full-bridge application, these bits should be set to 00. If ramp- up or down is needed, as in a single-ended half-bridge application, these bits must be used in the proper sequence as outlined in “Recommended Power-Up Sequence” on page 43 and “Recommended Power- Down Sequence” on page 45. 7.6.2 Ramp Speed (RAMP_SPD[1:0]) Default = 01 00 - Ramp speed = approximately 0.1 seconds 01 - Ramp speed = approximately 0.2 seconds 10 - Ramp speed = approximately 0.3 seconds 11 - Ramp speed = approximately 0.65 seconds Function: This feature is used in single-ended applications to reduce pops in the output caused by the DC-blocking capacitor. The Ramp Speed sets the time for the PWM signal to linearly ramp-up and down from the bias point (50% PWM duty cycle). Refer to Section 5.1.1 76 54 32 10 RESERVED RESERVED RESERVED RAMP1 RAMP0 RESERVED RAMP_SPD1 RAMP_SPD0 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |