| поискавой системы для электроныых деталей |
|
DSPIC33FJ12MC02ESS датащи(PDF) 168 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
DSPIC33FJ12MC02ESS датащи(HTML) 168 Page - Microchip Technology |
|
168 / 284 page ![]() dsPIC33FJ12MC201/202 DS70265B-page 166 Preliminary © 2007 Microchip Technology Inc. 15.1 Quadrature Encoder Interface Logic A typical incremental (or optical) encoder has three outputs: Phase A, Phase B and an index pulse. These signals are useful and often required in position and speed control of ACIM and SR motors. The two channels, Phase A (QEA) and Phase B (QEB), have a unique relationship. If Phase A leads Phase B, the direction of the motor is deemed positive or for- ward. If Phase A lags Phase B, the direction of the motor is deemed negative or reverse. A third channel, termed index pulse, occurs once per revolution and is used as a reference to establish an absolute position. The index pulse coincides with Phase A and Phase B, both low. 15.2 16-bit Up/Down Position Counter Mode The 16-bit up/down counter counts up or down on every count pulse, which is generated by the difference of the Phase A and Phase B input signals. The counter acts as an integrator whose count value is proportional to position. The direction of the count is determined by the UPDN signal, which is generated by the Quadrature Encoder Interface logic. 15.2.1 POSITION COUNTER ERROR CHECKING Position counter error checking in the QEI is provided for and indicated by the CNTERR bit (QEICON<15>). The error checking applies only when the position counter is configured for Reset on the Index Pulse modes (QEIM<2:0> = 110 or 100). In these modes, the contents of the POSCNT register are compared with the values (0xFFFF or MAXCNT + 1, depending on direction). If these values are detected, the CNTERR bit is set, generating an error condition, and a QEI counter error interrupt is generated. The QEI counter error interrupt can be disabled by setting the CEID bit (DFLTCON<8>). The position counter continues to count encoder edges after an error has been detected. The POSCNT regis- ter continues to count up/down until a natural rollover/ underflow. No interrupt is generated for the natural rollover/underflow event. The CNTERR bit is a read/write bit and is reset in software by the user application. 15.2.2 POSITION COUNTER RESET The Position Counter Reset Enable bit, POSRES (QEI<2>), controls whether the position counter is reset when the index pulse is detected. This bit is applicable only when QEIM<2:0> = 100 or 110. If the POSRES bit is set to ‘1’, the position counter is reset when the index pulse is detected. If the POSRES bit is set to ‘0’, the position counter is not reset when the index pulse is detected. The position counter con- tinues counting up or down, and is reset on the rollover or underflow condition. The interrupt is still generated on the detection of the index pulse and not on the position counter overflow/ underflow. 15.2.3 COUNT DIRECTION STATUS The QEI logic generates a UPDN signal, based upon the relationship between Phase A and Phase B. In addition to the output pin, the state of this internal UPDN signal is supplied to an SFR bit, UPDN (QEICON<11>), as a read-only bit. To place the state of this signal on an I/O pin, the SFR bit, PCDOUT (QEICON<6>), must be set to ‘1’. 15.3 Position Measurement Mode Two measurement modes are supported, x2 and x4. These modes are selected by the QEIM<2:0> mode select bits located in SFR QEICON<10:8>. When control bits QEIM<2:0> = 100 or 101, the x2 Measurement mode is selected and the QEI logic only looks at the Phase A input for the position counter increment rate. Every rising and falling edge of the Phase A signal causes the position counter to be incremented or decremented. The Phase B signal is still used for the determination of the counter direction. Within the x2 Measurement mode, there are two variations of how the position counter is reset: • Position counter reset by detection of index pulse, QEIM<2:0> = 100 • Position counter reset by match with MAXCNT, QEIM<2:0> = 101 When control bits QEIM<2:0> = 110 or 111, the x4 Measurement mode is selected and the QEI logic looks at both edges of the Phase A and Phase B input signals. Every edge of both signals causes the position counter to increment or decrement. Within the x4 Measurement mode, the position counter can be reset two ways: • Position counter reset by detection of index pulse, QEIM<2:0> = 110. • Position counter reset by match with MAXCNT, QEIM<2:0> = 111. The x4 Measurement mode provides for finer resolution data (more position counts) for determining motor position. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |