| поискавой системы для электроныых деталей |
|
MP5990 датащи(PDF) 65 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP5990 датащи(HTML) 65 Page - Monolithic Power Systems |
|
65 / 72 page ![]() MP5990 – 16V, 50A, 1mΩ, INTELLIGENT HOT-SWAP SOLUTION WITH PMBUS MP5990 Rev. 1.1 MonolithicPower.com 65 4/19/2024 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2024 MPS. All Rights Reserved. FAULT_RECORD (FAh) The FAULT_RECORD command stores all the current fault bits of system. The related bit is set to 1 if a fault occurs. Command FAULT_RECORD Format Unsigned binary Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Access R R R R R R R R R R R R R R R R Function X X X X Bits Bit Name Description 15 RESERVED Unused. X indicates that writes are ignored and reads are always 0. 14 NVM_CRC_FAULT Indicates whether a CRC fault has occurred. While storing the operating memory data to the NVM, the MP5990 calculates a CRC code for each bit and saves the final CRC code to the NVM. When restoring the NVM data to the operating memory, the MP5990 recalculates the CRC code for each bit. The MP5990 checks the CRC results when the restoration process is complete. If the CRC result does not match what is stored in the storing process, the VR shuts down and this bit is set. 1 ’b0: No NVM CRC fault has been detected 1 ’b1: An NVM CRC fault has been detected 13 NVM_SIG_FAULT While restoring data from the NVM to the memory, the device checks the signature register in address 00h of the NVM first. If the signature register is 0x1234, the restoration process stops immediately and this bit is set. 1 ’b0: No NVM signature fault has occurred 1 ’b1: An NVM signature fault has occurred 12 RESERVED Unused. X indicates that writes are ignored and reads are always 0. 11 OTP_CONTROLLER_ FAULT Indicates whether the controller experiences an over-temperature (OT) fault. Once the controller ’s temperature exceeds its OT threshold, this bit is set. 1 ’b0: No controller OT fault has occurred 1 ’b1: A controller OT fault has occurred 10 MAX_SS_FAULT Indicates whether the slave experiences a maximum SS fault. If the SS pin is still low when the maximum soft start time ends, this bit is set. 1 ’b0: No maximum SS fault has occurred 1 ’b1: A maximum SS fault has occurred 9 RESERVED Unused. X indicates that writes are ignored and reads are always 0. 8 VIN_OV_FAULT VIN over-voltage (OV) fault indicator. Once the sensed VIN exceeds the VIN OV fault limit, this bit is set. 1 ’b0: No VIN OV fault has occurred 1 ’b1: A VIN OV fault has occurred 7 RESERVED Unused. X indicates writes are ignored and reads are always 0. 6 SLAVE_GOK_FAULT Indicates whether a slave GOK fault has occurred. If a slave has faults, GOK pulls low and this bit is set. 1 ’b0: No slave faults have occurred 1 ’b1: A slave fault has occurred |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |