15 / 26 page ![]() Analog Integrated Circuit Device Data Freescale Semiconductor 15 34652 FUNCTIONAL DEVICE OPERATION PROTECTION FEATURES BOARD REMOVAL When the board is removed, its power ramps down. As soon as the 34652’s input voltage reaches the undervoltage turn-off threshold, the undervoltage detection circuit activates and the Power MOSFET turns off for having violated one of the start-up conditions (list on page 12). 34652 STATE MACHINE DIAGRAM Figure 13 is a representation of the 34652 behavior in different modes of operation. Figure 13. State Diagram PROTECTION FEATURES UNDERVOLTAGE When the voltage on the UV pin drops below the undervoltage falling threshold for more than 1.0 ms, an undervoltage fault is detected and one of the start-up conditions (list on page 12) is violated. The 34652 turns off the Power MOSFET and deactivates the power good output signals, disabling the load (Point A in Figure 14). The 34652 stays in this state until the voltage on the UV pin rises above the undervoltage rising threshold for more than 1.0 ms, signaling that the supply voltage is in the normal operation range (Point B in Figure 14). Then a new start-up sequence initiates as described on page 12. The undervoltage detection circuit is also equipped with a 1.0 V hysteresis when in default mode. The hysteresis value depends on the undervoltage detection threshold and can be calculated as follows: VUVHY = VUV(RISING) * [1 - (1.3 V - VUVCHY) / 1.3 V] Figure 14. Undervoltage Fault Followed by a New Start-Up Sequence MOSFET → OFF PG = 0 Undervoltage MOSFET → OFF PG = 0 Power Off Temp < 135°C Filter = 12 µs VPWR < VUVLOF Filter = 1.0 ms A signal “set” is generated to check resistors on UV, ILIM, ICHG, and TIMER pins and 128 µs later the OV pin Retry Fault STOP Toggle DISABLE or cycle Power Off then On to clear fault Power Good Check and VDS < 500 mV for 20 ms Charging Mode N ≤ 10 Turn Off MOSFET → OFF PG = 0 PG = 1 N = 0 VPWR > VUVLOR Filter = 1.0 ms Filter = 3.0 ms ILOAD > ILIM ILOAD < ILIM - ILIMHY Short Circuit Detection Fast Gate Discharge < 10 µs ILOAD > ISHORT Overcurrent for > 3.0 ms Pass PG Check Fail PG Check N > 10 for 100 µs VPWR < VUV(OFF) Filter = 1.0 ms MOSFET → OFF PG = 0 Overvoltage VPWR < VOV(ON) VPWR > VOV(OFF) Filter = 1.0 ms Filter = 1.0 ms PG = 0 MOSFET → OFF Temp > 160°C Filter = 12 µs Thermal Shutdown Ext. Resistor Check POR is generated N = 0 MOSFET → OFF PG = 0 DISABLE POR is generated N = 0 DISABLE = 1 Filter = 1.0 ms DISABLE = 0 Filter = 1.0 ms VPWR > VUV(ON) Filter = 1.0 ms If ILOAD < ILIM Overcurrent Mode Normal Operation VDS < 500 mV Start-Up Conditions • Thermal Shutdown < 160°C Filter = tTIMER • VPWR > VUV(OFF) • VPWR < VOV(OFF) N = N + 1 • DISABLE = 0 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |