21 / 60 page ![]() AD9995 –21– Sweep Mode Operation The AD9995 contains an additional mode of vertical timing operation called Sweep mode.This mode is used to generate a large number of repetitive pulses that span multiple HD lines. One example of where this mode is needed is at the start of the CCD readout operation. At the end of the image exposure but before the image is transferred by the sensor gate pulses, the vertical interline CCD registers should be free of all charge.This can be accomplished by quickly shifting out any charge using a long series of pulses from the V1–V6 outputs. Depending on the vertical resolution of the CCD, up to 2,000 or 3,000 clock cycles will be needed to shift the charge out of each vertical CCD line. This operation will span across multiple HD line lengths. Nor- mally, the AD9995’s vertical timing must be contained within one HD line length, but when Sweep mode is enabled, the HD boundaries will be ignored until the region is finished.To enable Sweep mode within any region, program the appropriate SWEEP register to high. Figure 21 shows an example of Sweep mode operation. The number of vertical pulses needed will depend on the vertical resolution of the CCD. The V1–V6 output signals are gener- ated using the V-pattern registers (shown in Table VII). A single pulse is created using the polarity and toggle position registers. The number of repetitions is then programmed to match the number of vertical shifts required by the CCD. Repetitions are programmed in the V-sequence registers using the VPATREP registers. This produces a pulse train of the appropriate length. Normally, the pulse train would be truncated at the end of the HD line length, but with Sweep mode enabled for this region, the HD boundaries will be ignored. In Figure 21, the Sweep region occupies 23 HD lines. After the Sweep mode region is completed, in the next region, normal sequence operation will resume. When using Sweep mode, be sure to set the region boundaries (using the sequence change positions) to the appro- priate lines to prevent the Sweep operation from overlapping the next V-sequence. Multiplier Mode To generate very wide vertical timing pulses, a vertical region may be configured into a multiplier region. This mode uses the V-pattern registers in a slightly different manner. Multiplier mode can be used to support unusual CCD timing requirements, such as vertical pulses that are wider than a single HD line length. The start polarity and toggle positions are still used in the same manner as the standard VPAT group programming, but the VPATLEN is used differently. Instead of using the pixel counter (HD counter) to specify the toggle position locations (VTOG1, 2, 3) of the VPAT group, the VPATLEN is multiplied with the VTOG position to allow very long pulses to be generated.To cal- culate the exact toggle position, counted in pixels after the start position, use the equation Multiplier ModeTogglePosition VTOG VPATLEN = × Because the VTOG register is multiplied by VPATLEN, the resolution of the toggle position placement is reduced. If VPATLEN = 4, the toggle position accuracy is now reduced to 4-pixel steps instead of single pixel steps. Table VIII sum- marizes how the VPAT group registers are used in Multiplier mode operation. In Multiplier mode, the VPATREPO and VPATREPE registers should always be programmed to the same value as the highest toggle position. VD V1–V6 HD REGION 1: SWEEP REGION LINE 0 L 0 LINE 1 REGION 0 REGION 2 LINE 24 LINE 25 LINE 2 SCP 1 SCP 2 Figure 21. Example of Sweep Region for High Speed Vertical Shift Table VIII. Multiplier Mode Register Parameters Register Length Range Description MULTI 1b High/Low High enables Multiplier mode. VPOL 1b High/Low Starting Polarity of V1–V6 Signal in Each VPAT Group. VTOG1 12b 0–4095 Pixel Location First Toggle Position for V1–V6 Signal in Each VPAT Group. VTOG2 12b 0–4095 Pixel Location Second Toggle Position for V1–V6 Signal in Each VPAT Group. VTOG3 12b 0–4095 Pixel Location Third Toggle Position for V1–V6 Signal in Each VPAT Group. VPATLEN 10b 0–1023 Pixels Used as Multiplier Factor for Toggle Position Counter. VPATREP 12b 0–4096 VPATREPE/VPATREPO should be set to the same value as TOG2 or 3. REV. 0 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |