| поискавой системы для электроныых деталей |
|
2000 датащи(PDF) 6 Page - Christian Bürkert GmbH & Co. KG |
|
|
|||||||||||||||||||||||||||||
2000 датащи(HTML) 6 Page - Christian Bürkert GmbH & Co. KG |
|
6 / 32 page ![]() Type 8640 6 | 32 Visit product website 1.2. Solenoid valves Type 6524 and Type 6525 • The pilot valves Type 6524 (single and double valve) and Type 6525 (single valve) consist of a pilot flipper solenoid valve Type 6144 and a pneumatic seat valve. • The operating principle allows switching of high pressures with low power consumption and short switching times. • The pilot valves are equipped with a manual override as standard. • The pneumatic flange pattern of the pilot valves Type 6524 and 6525 (single valves) for Type 8640 REV3 has been standardised. There is a difference to the flange pattern of the pilot valves for Type 8640 REV2. It is therefore imperative to take into account the different article numbers of the pilot valves as described in chapter “9.3. Ordering chart replacement valves” on page 23. • Further information about ordering information can be found in chapter “9.3. Ordering chart replacement valves” on page 23. • Further information about further valve options can be found in chapter “9.4. Ordering chart accessories” on page 27. Pilot valve Type Type 6524, Type 6525 Type 6524 Circuit function 3/2 and 5/2-way valve 2 × 3/2-way valve Product properties Materials Body PA (polyamide) Seal FKM, NBR and PUR Width per station 11 mm Manual override Standard Pneumatic module With plug-in coupling, Ø 6 mm, Ø ¼" Performance data Pressure data Overpressure to atmospheric pressure Flow rate Q Nn value air Measured at + 20 °C, 6 bar pressure at valve inlet and 1 bar difference pressure, see “9.3. Ordering chart replacement valves” on page 23. Duty cycle Continuous operation (100 % duty cycle) Switching time Measured according to ISO 12238 Electrical data Operating voltage 24 V DC (10 % residual ripple permissible) Nominal power of each valve 0.8 W 2 × 0.8 W with reduction of power Medium data Operating medium Oil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended) Process/Port connection & communication Service port 2 (A), 4 (B) Plug-in coupling Ø 6 mm, Ø ¼" Air supply connection 1 (P), 3 (R), 5 (S) G ¼ Electrical connection (on valve) Rectangular plug, 2-pin, grid spacing 5.08 mm Cable with strands 1.) Rectangular plug, 3-pin, grid spacing 2.54 mm Cable with strands 1.) Environment and installation Installation position As required, preferably with actuator upright Mounting condition With 2 screws M2 × 20 With 2 screws M2 × 28 1.) Versions with safety-related shutdown. The switching contact must be located in the same control cabinet as the valve block. The line length must be limited to a maximum of 2 m. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |