| поискавой системы для электроныых деталей |
|
PLC датащи(PDF) 4 Page - Christian Bürkert GmbH & Co. KG |
|
|
|||||||||||||||||||||||||||||
PLC датащи(HTML) 4 Page - Christian Bürkert GmbH & Co. KG |
|
4 / 11 page ![]() Type 8412 4 | 11 Visit product website Digital communication: CANopen Protocol CiA DS 301, V4.02, CANopen slave Profile CiA DS 404, V1.2; measuring devices and closed-loop controllers Baud rate 20 kbaud to 1 Mbaud, setting via LSS or SDO Node ID 1 to 127 setting via LSS or SDO PDO 0 Rx, 1 Tx SDO 1 Rx, 1 Tx Emergency Yes Heartbeat Yes (if active, then Node Guarding deactivated) Node Guarding Yes (if active, then Heartbeat deactivated) LSS Yes SYNC Yes Operation and project planning All parameters are accessible via the CANopen object directory (EDS) and can be set via standard CANopen software tools or Bürkert Communicator. EDS (electronic data sheet) • Device driver in Bürkert Communicator tool Type 8920, see “Bürkert Communicator” on the website in the Software chapter Type 8920 • See “Device Description Files” on the website in the Software chapter Type 8412 Factory setting See “Operating Instructions Type 8412“ on the website in the User Manuals chapter Type 8412 Approvals and certificates Directives CE directive The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable) Pressure equipment directive • The device does not meet the requirements for “safety accessories” within the meaning of the Pressure Equipment Directive 2014/68/EU. • Complying with article 4, paragraph 1 of 2014/68/EU directive Detailed information on the pressure equipment directive can be found in chapter “2.1. Pressure equipment directive” on page 5. Environment and installation Ambient temperature Operation - 20…+ 85 °C (- 4…+ 185 °F) Storage - 40…+ 85 °C (- 40…+ 185 °F) Temperature influence ≤ ± 0.0025 % of the measuring span per K deviation from 22 °C Relative air humidity • During operation: ≤ 100 %, without condensation on the outer housing surface of the device • During storage: ≤ 90 %, without condensation Climate class 3K7 according to EN 60721-3-3 Application range Indoors and outdoors (protect this device against electromagnetic interference, ultraviolet rays and the effects of climatic conditions) Degree of protection according to IEC/ EN 60529 IP67 with female connector screwed on Mounting position Installation: unrestricted |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |