| поискавой системы для электроныых деталей |
|
PLC датащи(PDF) 3 Page - Christian Bürkert GmbH & Co. KG |
|
|
|||||||||||||||||||||||||||||
PLC датащи(HTML) 3 Page - Christian Bürkert GmbH & Co. KG |
|
3 / 11 page ![]() Type 8412 3 | 11 Visit product website 1. General technical data Product properties Material Please make sure the device materials are compatible with the fluid you are using. Detailed information can be found in chapter “3.1. Chemical Resistance Chart – Bürkert resistApp” on page 5. Non wetted parts Housing Stainless steel 1.4571 (316Ti) Wetted parts Process connection • G or NPT variant: stainless steel 1.4571 (316Ti) • Clamp variant: stainless steel 1.4435 (316L) Protection tube • G or NPT variant: stainless steel 1.4571 (316Ti) • Clamp variant: stainless steel 1.4435 (316L) Dimensions Detailed information can be found in chapter “4. Dimensions” on page 6. Weight Approx. 80 g for the variant with thread connection and 100 mm probe length. The weight of the temperature sensor depends on the process connection and the inser- tion length. Measuring element Pt1000 temperature sensor, two-wire circuit Measuring probe length 25, 30, 50, 100 or 150 mm Measuring range - 50…+ 150 °C (- 58…+ 302 °F) Monitoring • Measuring circuit – Underrange (freely selectable lower limit) – Overrange (freely selectable upper limit) • Probe short circuit • Probe break Additional function • Min./max. measured value memory • Fine adjustment • Toggling between °C, °F, °K • Decimal places selectable 0, 1, 2 Performance data Sampling rate 250 ms Transmission behaviour Temperature linear Measuring resolution 12 Bit Measurement deviation • Tolerance class A according to EN 60751:2009 / IEC 60751:2008 • Max. ± 0.2 % of the measuring range span Response time • t 0.5 = 5 s; t0.9 = 12 s, in water with a flow velocity of 0.4 m/s • t 0.5 = 40 s; t0.9 = 110 s, in air with a flow velocity of 3.0 m/s Electrical data Operating voltage 10…30 V DC, filtered and regulated Power source (not supplied) The auxiliary energy of the pressure sensor must meet SELV requirements; optionally, an energy-limited current circuit according to section 9.3 of DIN EN 31010-1 and UL 61010-1 can be used. DC reverse polarity protection Yes Overvoltage protection Yes Short circuit protection Yes Protection class Class III according to EN 61140 Current consumption Approx. max. 45 mA Recommended connection cable 5-wire shielded cable, length depends on the transmission speed. The physical CAN transmission is standardized according to ISO 11898-2 (high-speed) and ISO 11898-3 (low-speed) Medium data Fluid Liquid and gaseous medium Fluid pressure Max. 40 bar Process/Pipe connection & communication Process connection • G ½" or NPT ½" screw-in thread according to EN 837 • Clamp ¾" according to DIN 32676 series B Electrical connection M12 × 1 male connector, 5 pin according to DIN IEC 60947-5-2 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |