7 / 17 page ![]() Type 8232 7 | 17 Visit product website Sensor model Free chlorine sensor “Trace” (zero-chlorine) Free chlorine sensor with 3 electrodes Free chlorine sensor with 2 electrodes Total chlorine sensor with 3 electrodes Fluid pressure Max. 0.5 bar (7.26 PSI), operation with or with- out retaining ring, no pressure drops and/or vibrations • Max. 3.0 bar (43.53 PSI), operation with retaining ring, no pressure drops and/ or vibrations • Max. 0.5 bar (7.26 PSI), operation without retaining ring, no pressure drops and/or vibrations • Max. 1 bar (14.5 PSI), operation with retaining ring, no pressure drops and/ or vibrations • Max. 0.5 bar (7.26 PSI), operation without retaining ring, no pressure drops and/or vibrations • Max. 3.0 bar (43.53 PSI), operation with retaining ring, no pressure drops and/ or vibrations • Max. 0.5 bar (7.26 PSI), operation without retaining ring, no pressure drops and/or vibrations If the pressure ranges given for the holder and the used sensor are different, use the most restrictive range. Pressure drops are not allowed; the membrane could be damaged Process/Pipe connection & communication Process connection With probe holder Type 8200, see data sheet Type 8200 . Electrical connection 5-pin M12 circular male connector 5-pin M12 circular male connector 5-pin M12 circular male connector 5-pin M12 circular male connector Approvals and certificates Directives CE directive The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable). Environment and installation Ambient temperature Operation 0…+ 55 °C (+ 32…+ 131 °F) Storage • Probe: unlimited time at + 5…+ 40 °C (+ 41…+ 104 °F), frost protected, dry and without electrolyte • Membrane cap: – in original packing unlimited time at + 5…+ 40 °C (+ 41…+ 104 °F) – used membrane caps cannot be stored • Electrolyte: + 5…+ 35 °C (+ 41…+ 95 °F), 1 year or until the specified expiry date in original bottle protected from sunlight Transport + 5…+ 50 °C (+ 41…+ 122 °F) + 5…+ 55 °C (+ 41…+ 131 °F) + 5…+ 50 °C (+ 41…+ 122 °F) + 5…+ 50 °C (+ 41…+ 122 °F) Relative air humidity ≤ 90 %, without condensation Height above sea level Max. 2000 m Degree of protection ac- cording to IEC/EN 60529 IP65 with cable plug mounted and tightened 1.) Avoids fouling effects on the membrane in water without any chlorine for up to four weeks. 2.) Depends strongly on the water quality; values are recommendations for drinking water quality. 3.) Analogue input board necessary. Software variant of input board must be A.03.00 or higher; otherwise contact your local Bürkert support. 4.) A potential-free electrical connection is necessary as the chlorine sensor is not equipped with a galvanic isolation. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |