4 / 17 page ![]() Type 8232 4 | 17 Visit product website Sensor model Free chlorine sensor “Trace” (zero-chlorine) Free chlorine sensor with 3 electrodes Free chlorine sensor with 2 electrodes Total chlorine sensor with 3 electrodes Cross sensitivity/Inter- ference • ClO 2, O3 influence the signal strongly. • High concentrations of bound chlorine can increase the meas- ured value. • Corrosion inhibitors, Stabilisers for water hardness can lead to measuring errors. • Reducing agents can lead to a loss in slope. • ClO 2 (factor 0.75), O3 (factor 0.8) influence the signal. • High concentrations of bound chlorine can increase the meas- ured value. • Corrosion inhibitors, Stabilisers for water hardness can lead to measuring errors. • ClO 2 (factor 9), O3 influence the signal. • Electrolytically gener- ated chlorine with a cell without mem- brane can disturb measurement. • ClO 2 (factor 1) • O 3 (factor 1.3) • Corrosion inhibitors, Stabilisers for water hardness can lead to measuring errors. Maintenance2.) Control of the measuring signal Min. once a week rec- ommended Min. once a week rec- ommended Min. once a week rec- ommended Min. once a week rec- ommended Change of the mem- brane cap Once a year recom- mended Once a year recom- mended Once a year recom- mended Once a year recom- mended Change of the electrolyte Every 3…6 months recommended Once a year recom- mended Every 3…6 months recommended Once a year recom- mended Product accessories Membrane cap M48.2 with intern holder (G-holder) M48.4E (M48.4S for sea water on request) M20.2 M48.4E (M48.4S for sea water or brine on request) Chlorination agent Inorganic chlorine com- pounds: • NaOCl (sodium hy- pochlorite) • Ca(OCl) 2 • Chlorine gas • Electrolytically gener- ated chlorine Inorganic chlorine com- pounds: • NaOCl (sodium hy- pochlorite) • Ca(OCl) 2 • Chlorine gas • Electrolytically gener- ated chlorine Inorganic chlorine com- pounds: • NaOCl (sodium hy- pochlorite) • Ca(OCl) 2 • Chlorine gas • Chlorine electrolysis with membrane cell (unsuitable: chlorine electrolysis without membrane cell) Inorganic chlorine com- pounds: • NaOCl (sodium hy- pochlorite) • Ca(OCl) 2 • Chlorine gas • Electrolytically gener- ated chlorine Suitable transmitter Type 8619 multiCELL Transmitter/Controller3.) or any transmitter with appropriate input Further accessory • Photometer MD100 • DPD-1 reagent • External calibration device • Photometer MD100 • DPD-1 reagent • Photometer MD100 • DPD-1 reagent • Photometer MD100 • DPD-4 reagent • DPD-1 + DPD-3 reagents Detailed information can be found in chapter “9.5. Ordering chart accessories” on page 16. Performance data Sensor resolution 0.001 ppm 0.01 ppm 0.01 ppm 0.01 ppm Run-in time After first start-up and maintenance operations approx. 2 hours After first start-up and maintenance operations approx. 2 hours After first start-up and maintenance operations approx. 1 hour After first start-up and maintenance operations approx. 2 hours Response time (t90 %) Approx. 120 s Approx. 120 s Approx. 30 s Approx. 3 min. (brine approx. 5 min.) Sensor reactivity loss After max. 4 weeks use in chlorine-free water After max. 24 hours use in chlorine-free water After max. 24 hours use in chlorine-free water After max. 24 hours use in chlorine-free water |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |