| поискавой системы для электроныых деталей |
|
VCM095 датащи(PDF) 11 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
VCM095 датащи(HTML) 11 Page - List of Unclassifed Manufacturers |
|
11 / 20 page ![]() 28 Mechanical pressure switches Pressure switch with locking of switching state (reclosing lockout) Pressure switch with switching state locking (reclosing lockout) In the case of limiter functions, the switching state must be retained and locked, and it may be unlocked and the system restarted only after the cause of the safety shutdown has been eliminated. There are two ways of doing this: 1. Mechanical locking inside the pressure switch Instead of a microswitch with automatic reset, limiters contain a "bi-stable" microswitch. If the pressure reaches the value set on the scale, the microswitch trips over and remains in this position. The lock can be released by pressing the unlocking button (identified by a red dot on the scale side of the switching device). The lock can operate with rising or falling pressure, depending on the version. The device can only be unlocked when the pressure has been reduced (or increased) by the amount of the predefined switching differential. When selecting a pressure limiter, it is necessary to distinguish between maximum and minimum pressure monitoring. Ex-d versions cannot be equipped with internal locking. Maximum pressure limitation Minimum pressure limitation Switching and interlock- Switching and interlocking ing with rising pressure. with falling pressure. Additional function Additional function ZF205. ZF206. Connection of control Connection of control current circuit to current circuit to terminals 1 and 3. terminals 2 and 3. 2. External electrical interlock in the control cabinet (suggested circuits) A pressure monitor (microswitch with automatic reset) can also be used as a limiter if an electrical interlock is added. For pressure limitation in steam and hot water boilers, an external interlock is only permitted if it has been ascertained that the pressure monitor is "of special construction". Maximum pressure limitation Minimum pressure limitation with external interlock with external interlock Where the above lock circuit is used, the requirements of DIN 57 116/VDE 0116 are met if the electrical equipment (such as contactors or relays) of the external interlock circuit satisfy VDE 0660 or VDE 0435. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |