| поискавой системы для электроныых деталей |
|
VCM095 датащи(PDF) 17 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
VCM095 датащи(HTML) 17 Page - List of Unclassifed Manufacturers |
|
17 / 20 page ![]() 34 Mechanical pressure switches S2 type series Switching scheme Switching device Ordering position Additional text A1 A DCM6-217A-S Switching scheme A1 A2 C DCM6-217C-S Switching scheme A2 A3 C DCM6-217C-S Switching scheme A3 A4 A DCM6-217A-S Switching scheme A4 B1 B DCM6-217B-S Switching scheme B1 B2 D DCM6-217D-S Switching scheme B2 B3 D DCM6-217D-S Switching scheme B3 B4 B DCM6-217B-S Switching scheme B4 C1 B DCM6-217B-S Switching scheme C1 C2 D DCM6-217D-S Switching scheme C2 C3 D DCM6-217D-S Switching scheme C3 C4 B DCM6-217B-S Switching scheme C4 D1 A DCM6-217A-S Switching scheme D1 D2 C DCM6-217C-S Switching scheme D2 D3 C DCM6-217C-S Switching scheme D3 D4 A DCM6-217A-S Switching scheme D4 Note on ordering additional function ZF217 FEMA pressure switches of the DCM (except DCM1000, DCM4016 and DCM4025), VCM (except VCM4156), VNM, DNS, VNS series can be equipped with 2 microswitches. This is not possible with any other type series or with Ex versions. Technical data Standard equipment The standard equipment of every two-stage pressure switch includes a switching device with 2 microswitches, both single-pole switching. Switch I monitors the low pressure, switch II the higher pressure. The setting ranges indicated in the data sheets for the basic types apply to the two-stage pressure switches as well. It should be noted that the switching differentials of the individual microswitches may not be exactly the same due to component tolerances. Switching difference The switching interval of the two microswitches is the difference (in bar or mbar) between the switching points of the two micro switches. Example for ZF307: When the pressure rises (e.g. 2.8 bar), a two-stage pressure switch turns on a warning light, and if the pressure continues to rise (e.g. 3.2 bar) the system shuts down. The switching interval is 3.2-2.8 = 0.4 bar. The following applies to all versions: The switching interval remains constant over the whole setting range of the pressure switch. If the switching pressure setting is changed with the setting spindle, the switching interval does not change - the switching points are moved in parallel. Switching differential The switching differential, i.e. the hysteresis of the individual micro switches, corresponds to the values of the relevant basic version referred to in the Product summary. In the case of two-stage pressure switches, the switching differential of the individual micro switches is not adjustable. Versions Two-stage pressure switches are available in three different versions, each identified by a ZF number. The versions differ in terms of their connection schemes and electrical connection types (terminal or plug connection). S2 type series Pressure switches with 2 microswitches - technical data The applicable data sheet for the basic types contains the technical data for the two-stage pressure switches. This includes all limits of use, such as temperature, maximum pressure, mounting position, protection class, electrical data etc. The principal dimensions are the same as for single-stage pressure switches with comparable pressure ranges and design features. ZF307 Factory setting according to customer’s instruction Switching difference fixed Terminal connection (All terminals of both microswitches are accessible (6 terminals) 2 x single-pole switching 1. Basic type with ZF 307 2. Switching points I and II, with direction of action in each case (rising or falling pressure) Example: DCM16-307 Switching point I: 10 bar falling Switching point II: 12 bar falling or switching interval only. ZF217 Adjustable via adjustment knobs I and II in accordance with "Switching difference" table Plug connection in accordance with DIN EN175301 (3-prong + earth conductor) Function- appropriate internal wiring in accordance with "Switching functions" table Example selection in accordance with "Switching schemes" table, page 36. 1. Basic type with ZF217 2. Switching scheme For example: DCM16-217/B 4 Since all values are adjustable within the specified limits, no further data is required. Additional Switching difference Electrical Connection Ordering function between the two connection diagram information required micro switches |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |