13 / 30 page ![]() LOG114 SBOS301A − MAY 2004 − REVISED MARCH 2007 www.ti.com 13 DESIGN EXAMPLE FOR DUAL-SUPPLY CONFIGURATION Given these conditions: D V+ = 5V and V− = −5V D 100pA ≤ Input signal D The stage following the LOG114 is an analog-to- digital converter (ADC) with +5V supply and +2.5V reference voltage, so VO4 swings from +0.5V to +2.5V. 1. Due to LOG114 symmetry, you can choose either I1 or I2 as the signal input pin. Choosing I1 as the reference makes the resistor network around A4 simpler. (Note: Current must flow into pins 3 (I1) and pin 4 (I2).) 2. Select the magnitude of the reference current. Since the signal (I2) spans eight decades, set I1 to 1 µA − four decades above the minimum I2 value. (Note that it does not have to be placed in the middle. If I2 spanned seven decades, I1 could be set three decades above the minimum and four decades below the maximum I2 value.) This configuration results in more swing amplitude in the negative direction, which provides more sensitivity ( ∆VO4 per ∆I2) when the current signal decreases. 3. Using Equation (1) calculate the expected range of log outputs at VLOGOUT: For I 2 + 10mA : V LOGOUT + 0.375 log I 1 I 2 + 0.375 log 1 mA 10mA +* 1.5V For I 2 + 100pA : V LOGOUT + 0.375 log I 1 I 2 + 0.375 log 1 mA 100pA +) 1.5V Therefore, the expected voltage range at the output of amplifier A3 is: * 1.5V v V LOGOUT v) 1.5V 4. The A4 amplifier scales and offsets the VLOGOUT signal for use by the ADC using the equation: V O4 +*SFACTOR V LOGOUT ) VOFFSET The A4 amplifier is specified with a rated output swing capability from (V−) +0.5V to (V+) − 0.5V. Therefore, choose the final A4 output: 0V ≤ VO4 ≤ +2.5V This output results in a 2.5V range for the 3V VLOGOUT range, or 2.5V/3V scaling factor. 5. When I2 = 10mA, VLOGOUT = −1.5V. Using the equation in step 5: V O4 +*SFACTOR V LOGOUT ) VOFFSET 0V +*2.5V 3V(*1.5V) ) V OFFSET Therefore, VOFFSET = 0V The A4 amplifier configuration for VO4 = −2.5/3(VLOGOUT) + 0V is seen in Figure 3. The overall transer function is: V O4 +*0.249 log I 1 I 2 ) 1.5V A 4 Internal A4 Output Amplifier R 5 100k Ω V REF +2.5V V LOGOUT V O4 = − 2/3 (VLOGOUT) I 2 100pA 10mA A 4 amplifier usedtoscale andoffset VLOGOUT for 0V to 2.5V output. R 6 82.5k Ω R 7 100k Ω R 8 37.4k Ω V O4 0V +2.5V +5V −5V Figure 3. Operational Amplifier Configuration for Scaling the Output Going to ADC Stage. (3) (4) (5) (6) (7) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |