| поискавой системы для электроныых деталей |
|
3946 датащи(PDF) 5 Page - Allegro MicroSystems |
|
|
|||||||||||||||||||||||||||||
3946 датащи(HTML) 5 Page - Allegro MicroSystems |
|
5 / 13 page ![]() 5 Worcester, Massachusetts 01615-0036 (508) 853-5000 115 Northeast Cutoff, Box 15036 www.allegromicro.com 3946 Half-Bridge Power MOSFET Controller VREG. A 13 V output from the on-chip charge pump, used to power the low-side gate drive circuit directly, provides the current to charge the bootstrap capacitors for the high-side gate drive. The VREG capacitor, C REG, must supply the instantaneous current to the gate of the low-side MOSFET. A 10 μF, 25 V capacitor should be adequate. This capacitor can be either electrolytic or ceramic (X7R). Diagnostics and Protection . The fault output pin, ~FAULT, goes low (i.e., FAULT = 1) when the RESET line is high and any of the following conditions are present: • Undervoltage conditions on VREG (UVREG) or on the internal logic supply VREF (UVREF). These conditions set a latched fault. • A junction temperature > 170°C (OVERTEMP). This con- dition sets a latched fault. • An undervoltage on the stored charge of the BOOT capaci- tor (UVBOOT). This condition does NOT set a latched fault. An overtemperature event signals a latched fault, but does not disable any output drivers, regulators, or logic inputs. The user must turn off the A3946 (e.g., force the RESET line low) to prevent damage. The power FETs are protected from inadequate gate drive voltage by undervoltage detectors. Either of the regulator undervoltage faults (UVREG or UVREF) disable both output drivers until both voltages have been restored. The high-side driver is also disabled during a UVBOOT fault condition. Under many operating conditions, both the high-side (GH) and low-side (GL) drivers may be off, allowing the BOOT capacitor to discharge (or never become charged) and create a UVBOOT fault condition, which in turn inhibits the high- side driver and creates a FAULT = 1. This fault is NOT latched. To remove this fault, momentarily turn on GL to charge the BOOT capacitor. Latched faults may be cleared by a low pulse, 1 to 10 μs wide, on the RESET line. Throughout that pulse (despite a possible UVBOOT), FAULT = 0; also the fault latch is cleared immediately, and remains cleared. If the power is restored (no UVREG or UVREF), and if no OVERTEMP fault exists, then the latched fault remains cleared when the RESET line returns to high. However, FAULT = 1 may still occur because a UVBOOT fault condition may still exist. Charge Pump . The A3946 is designed to accommodate a wide range of power supply voltages. The charge pump output, VREG, is regulated to 13 V nominal. In all modes, this regulator is current-limited. When V BB < 8 V, the charge pump operates as a voltage doubler. When 8V < V BB< 15 V, the charge pump operates as a voltage doubler/PWM, current-controlled, voltage regulator. When V BB>15 V, the charge pump operates as a PWM, current-con- trolled, voltage regulator. Efficiency shifts, from 80% at V BB= 7 V, to 20% at V BB = 50 V. CAUTION. Although simple paralleling of VREG supplies from several A3946s may appear to work correctly, such a configuration is NOT recommended. There is no assurance that one of the regulators will not dominate, taking on all of the load and back-biasing the other regulators. (For example, this could occur if a particular regulator has an internal refer- ence voltage that is higher that those of the other regulators, which would force it to regulate at the highest voltage.) Sleep Mode/Power Up . In Sleep Mode, all circuits are disabled in order to draw minimum current from VBB. When powering up and leaving Sleep Mode (the RESET line is high), the gate drive outputs stay disabled and a fault remains asserted until VREF and VREG pass their undervoltage thresholds. When powering up, before starting the first boot- strap charge cycle, wait until t = C REG ⁄ 4 (where CREG is in μF, and t is in ns) to allow the charge pump to stabilize. When powered-up (not in Sleep Mode), if the RESET line is low for > 10 μs, the A3946 may start to enter Sleep Mode (V REF < 4 V). In that case, ~FAULT = 1 as long as the RESET line remains low. If the RESET line is open, the A3946 should go into Sleep Mode. However, to ensure that this occurs, the RESET line must be grounded. Functional Description |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |