| поискавой системы для электроныых деталей |
|
CS4412 датащи(PDF) 14 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS4412 датащи(HTML) 14 Page - Cirrus Logic |
|
14 / 22 page ![]() 14 DS749A1 CS4412 4.2.3 Recommended Power-Down Sequence 1. Mute the logic-level PWM inputs present on IN1 - IN4 by applying 50 % duty-cycle inputs. 2. Set RSTx/y low. If the CS4412 is configured for ramping, the outputs will ramp down to PGND and then become HI-Z. If the CS4412 is not configured for ramping, the outputs will immediately become HI-Z. 3. Power down the remainder of the system. 4. Turn off the system power. 4.3 Output Mode Configuration The CS4412 can be configured for several modes of operation. Table 2 shows the setting of the CNFG[2:0] inputs and the corresponding mode of operation. These pins should remain static during operation (RSTx/y set high). CNFG2 CNFG1 CNFG0 Output Config. Description 0 0 0 Stereo Full-Bridge Tied Loads IN1 must be inverted from IN2 for full-bridge operation. IN3 must be inverted from IN4 for full-bridge operation. 0 0 1 Stereo Half-Bridge and Mono Full- Bridge Tied Loads IN1 must be provided for half-bridge operation. IN2 must be provided for half-bridge operation. IN3 must be inverted from IN4 for full-bridge operation. 0 1 0 Mono Parallel Full- Bridge Tied Load IN1 and IN3 must be inverted from IN2 and IN4 for parallel full- bridge operation. 0 1 1 Quad Half-Bridge Tied Loads IN1 must be provided for half-bridge operation. IN2 must be provided for half-bridge operation. IN3 must be provided for half-bridge operation. IN4 must be provided for half-bridge operation. 1 0 0 Stereo Full-Bridge Tied Loads With Inversion IN1 must be provided for full-bridge operation. Wire IN2 to IN1. IN2 is internally inverted for full-bridge operation. IN3 must be provided for full-bridge operation. Wire IN4 to IN3. IN4 is internally inverted for full-bridge operation. 1 0 1 Stereo Half-Bridge & Mono Full-Bridge Tied Loads With Inversion IN1 must be provided for half-bridge operation. IN2 must be provided for half-bridge operation. IN3 must be provided for full-bridge operation. Wire IN4 to IN3. IN4 is internally inverted for full-bridge operation. 1 1 0 Mono Parallel Full- Bridge Tied Load With Inversion IN1 must be provided for parallel full-bridge operation. Wire IN4, IN3, and IN2 to IN1. IN2 and IN4 are internally inverted for parallel full-bridge operation. 1 1 1 Quad Half-Bridge Tied Loads IN1 must be provided for half-bridge operation. IN2 must be provided for half-bridge operation. IN3 must be provided for half-bridge operation. IN4 must be provided for half-bridge operation. Table 2. Output Mode Configuration Options |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |