Back Button 74HCT280 Datasheet HTML 3Page - Nexperia B.V. All rights reserved 74HCT280 Datasheet HTML 4Page - Nexperia B.V. All rights reserved 74HCT280 Datasheet HTML 5Page - Nexperia B.V. All rights reserved 74HCT280 Datasheet HTML 6Page - Nexperia B.V. All rights reserved 74HCT280 Datasheet HTML 7Page - Nexperia B.V. All rights reserved 74HCT280 Datasheet HTML 8Page - Nexperia B.V. All rights reserved 74HCT280 Datasheet HTML 9Page - Nexperia B.V. All rights reserved 74HCT280 Datasheet HTML 10Page - Nexperia B.V. All rights reserved 74HCT280 Datasheet HTML 11Page - Nexperia B.V. All rights reserved Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 13 page
background image
Nexperia
74HC280; 74HCT280
9-bit odd/even parity generator/checker
25 °C
-40 °C to +85 °C -40 °C to +125 °C
Symbol Parameter Conditions
Min Typ Max
Min
Max
Min
Max
Unit
74HCT280
In to PE; see Fig. 5
[1]
VCC = 4.5 V
-
21
42
-
53
-
63
ns
VCC = 5.0 V; CL = 15 pF
-
18
-
-
-
-
-
ns
In to PO; see Fig. 5
VCC = 4.5 V
-
26
45
-
56
-
68
ns
tpd
propagation
delay
VCC = 5.0 V; CL = 15 pF
-
22
-
-
-
-
-
ns
see Fig. 5
[2]
tt
transition
time
VCC = 4.5 V
-
7
15
-
19
-
22
ns
CPD
power
dissipation
capacitance
per package;
VI = GND to VCC - 1.5 V
[3]
-
65
-
-
-
-
-
pF
[1] tpd is the same as tPHL and tPLH.
[2] tt is the same as tTHL and tTLH.
[3] CPD is used to determine the dynamic power dissipation (PD in μW):
PD = CPD × VCC 2 × fi × N + ∑(CL × VCC 2 × fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = output load capacitance in pF;
VCC = supply voltage in V;
N = number of inputs switching;
∑(CL × VCC 2 × fo) = sum of outputs.
10.1. Waveforms and test circuit
aaa-024427
In input
VI
GND
VOH
VOL
PE, PO output
tTHL
tTLH
VM
VM
VX
VY
tPHL
tPLH
Measurement points are given in Table 8.
VOL and VOH are typical voltage output levels that occur with the output load.
Fig. 5. Input (In) to output (PE, PO) propagation delays and output transition times
Table 8. Measurement points
Input
Output
Type
VM
VM
VX
VY
74HC280
0.5VCC
0.5VCC
0.1VCC
0.9VCC
74HCT280
1.3 V
1.3 V
0.1VCC
0.9VCC
74HC_HCT280
All information provided in this document is subject to legal disclaimers.
© Nexperia B.V. 2021. All rights reserved
Product data sheet
Rev. 4 — 16 August 2021
7 / 13



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com