| поискавой системы для электроныых деталей |
|
MAX6602UE9A+ датащи(PDF) 11 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX6602UE9A+ датащи(HTML) 11 Page - Maxim Integrated Products |
|
11 / 18 page ![]() In both cases, the alert is cleared even if the fault condi- tion exists, but the ALERT output reasserts at the end of the next conversion. The bits indicating the fault for the OVERT interrupt output clear only on reading the status 2 register even if the fault conditions still exist. Reading the status 2 register does not clear the OVERT interrupt out- put. To eliminate the fault condition, either the measured temperature must drop below the temperature threshold minus the hysteresis value (4°C), or the trip temperature must be set at least 4°C above the current temperature. Five-Channel Precision Temperature Monitor ______________________________________________________________________________________ 11 REGISTER ADDRESS (hex) POR STATE (hex) READ/ WRITE DESCRIPTION Local 07 00 R Read local temperature register Remote 1 01 00 R Read channel 1 remote temperature register Remote 2 02 00 R Read channel 2 remote temperature register Remote 3 03 00 R Read channel 3 remote temperature register Remote 4 04 00 R Read channel 4 remote temperature register Configuration 1 41 00 R/W Read/write configuration register 1 Configuration 2 42 00 R/W Read/write configuration register 2 Configuration 3 43 00 R/W Read/write configuration register 3 Status1 44 00 R Read status register 1 Status2 45 00 R Read status register 2 Status3 46 00 R Read status register 3 Local ALERT High Limit 17 5A R/W Read/write local alert high-temperature threshold limit register Remote 1 ALERT High Limit 11 6E R/W Read/write channel 1 remote-diode alert high-temperature threshold limit register Remote 2 ALERT High Limit 12 7F R/W Read/write channel 2 remote-diode alert high-temperature threshold limit register Remote 3 ALERT High Limit 13 64 R/W Read/write channel 3 remote-diode alert high-temperature threshold limit register Remote 4 ALERT High Limit 14 64 R/W Read/write channel 4 remote-diode alert high-temperature threshold limit register Remote 1 OVERT High Limit 21 6E R/W Read/write channel 1 remote-diode overtemperature threshold limit register Remote 4 OVERT High Limit 24 7F R/W Read/write channel 4 remote-diode overtemperature threshold limit register Remote 1 Extended Temperature 09 00 R Read channel 1 remote-diode extended temperature register Manufacturer ID 0A 4D R Read manufacturer ID Table 3. Command Byte Register Bit Assignment |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |