8 / 18 page ![]() conversion results until they have been read. If the most significant bits have not been read within an SMBus timeout period (nominally 37ms), normal updat- ing continues. Table 1 shows the main temperature register (high byte) data format, and Table 2 shows the extended resolution register (low byte) data format. Diode Fault Detection If a channel’s input DXP_ and DXN_ are left open or short- ed together, the MAX6602 detects a diode fault. A diode fault, whether a short or an open circuit, does not cause either ALERT or OVERT to assert. A bit in the status regis- ter for the corresponding channel is set to 1 and the tem- perature data for the channel is stored as all 1s. It takes approximately 4ms for the MAX6602 to detect a diode fault. Once a diode fault is detected, the MAX6602 jumps onto the next channel in the conversion sequence. Five-Channel Precision Temperature Monitor 8 _______________________________________________________________________________________ Write Byte Format Read Byte Format Send Byte Format Receive Byte Format Slave Address: equiva- lent to chip-select line of a 3-wire interface Command Byte: selects to which register you are writing Data Byte: data goes into the register set by the command byte (to set thresholds, configuration masks, and sampling rate) Slave Address: equiva- lent to chip-select line Command Byte: selects from which register you are reading Slave Address: repeated due to change in data- flow direction Data Byte: reads from the register set by the command byte Command Byte: sends com- mand with no data, usually used for one-shot command Data Byte: reads data from the register commanded by the last read byte or write byte transmission; also used for SMBus alert response return address S = Start condition Shaded = Slave transmission P = Stop condition /// = Not acknowledged S ADDRESS RD ACK DATA /// P 7 bits 8 bits WR S ACK COMMAND ACK P 8 bits ADDRESS 7 bits P 1 ACK DATA 8 bits ACK COMMAND 8 bits ACK WR ADDRESS 7 bits S S ADDRESS WR ACK COMMAND ACK S ADDRESS 7 bits 8 bits 7 bits RD ACK DATA 8 bits /// P Figure 2. SMBus Protocols TEMP (°C) DIGITAL OUTPUT > +127 0111 1111 +127 0111 1111 +126 0111 1110 +25 0001 1001 0 0000 0000 < 0 0000 0000 Diode fault (short or open) 1111 1111 Table 1. Main Temperature Register (High Byte) Data Format TEMP (°C) DIGITAL OUTPUT 0 000X XXXX +0.125 001X XXXX +0.250 010X XXXX +0.375 011X XXXX +0.500 100X XXXX +0.625 101X XXXX +0.725 110X XXXX +0.875 111X XXXX Table 2. Extended Resolution Temperature Register (Low Byte) Data Format |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |