19 / 36 page ![]() ADM1063 Rev. 0 | Page 19 of 36 SEQUENCE DETECTOR The sequence detector block is used to detect when a step in a sequence has been completed. It looks for one of the inputs to the SE to change state and is most often used as the gate for successful progress through a power-up or power-down sequence. A timer block is included in this detector, which can insert delays into a power-up or power-down sequence if required. Timer delays can be set from 10 µs to 400 ms. Figure 28 is a block diagram of the sequence detector. SUPPLY FAULT DETECTION LOGIC INPUT CHANGE OR FAULT DETECTION WARNINGS FORCE FLOW (UNCONDITIONAL JUMP) VP1 VX5 INVERT SEQUENCE DETECTOR SELECT TIMER Figure 28. Sequence Detector Block Diagram The sequence detector can also help to identify monitoring faults. In the sample application shown in Figure 27, the FSEL1 and FSEL2 states identify which of the VP1,VP2, or VP3 pins has faulted, and then they take the appropriate action. MONITORING FAULT DETECTOR The monitoring fault detector block is used to detect a failure on an input. The logical function implementing this is a wide OR gate, which can detect when an input deviates from its expected condition. The clearest demonstration of the use of this block is in the POWER_GOOD state, where the monitor block indicates that a failure on one or more of the VP1, VP2, or VP3 inputs has occurred. No programmable delay is available in this block, because the triggering of a fault condition is likely to be caused when a supply falls out of tolerance. In this situation, the user should react as quickly as possible. Some latency occurs when moving out of this state, because it takes a finite amount of time (~20 µs) for the state configuration to download from EEPROM into the SE. Figure 29 is a block diagram of the monitoring fault detector. SUPPLY FAULT DETECTION LOGIC INPUT CHANGE OR FAULT DETECTION VP1 VX5 MONITORING FAULT DETECTOR MASK SENSE 1-BIT FAULT DETECTOR FAULT WARNINGS MASK 1-BIT FAULT DETECTOR FAULT MASK SENSE 1-BIT FAULT DETECTOR FAULT Figure 29. Monitoring Fault Detector Block Diagram TIMEOUT DETECTOR The timeout detector allows the user to trap a failure and, thus ensuring proper progress through a power-up or power- down sequence. In the sample application shown in Figure 27, the timeout next- state transition is from the EN3V3 and EN2V5 states. For the EN3V3 state, the signal 3V3ON is asserted on the PDO1 output pin upon entry to this state to turn on a 3.3 V supply. This supply rail is connected to the VP2 pin, and the sequence detector looks for the VP2 pin to go above its UV threshold, which is set in the supply fault detector (SFD) attached to that pin. The power-up sequence progresses when this change is detected. If, however, the supply fails (perhaps due to a short circuit over- loading this supply), the timeout block traps the problem. In this example, if the 3.3 V supply fails within 10 ms, the SE moves to the DIS3V3 state and turns off this supply by bringing PDO1 low. It also indicates that a fault has occurred by taking PDO3 high. Timeout delays of 100 µs to 400 ms can be programmed. FAULT REPORTING The ADM1063 has a fault latch for recording faults. Two registers are set aside for this purpose. A single bit is assigned to each input of the device, and a fault on that input sets the relevant bit. The contents of the fault register can be read out over the SMBus to determine which input(s) faulted. The fault register can be enabled/disabled in each state. This ensures that only real faults are captured and not, for example, undervoltage trips when the SE is executing a power-down sequence. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |