| поискавой системы для электроныых деталей |
|
L8150 датащи(PDF) 20 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L8150 датащи(HTML) 20 Page - STMicroelectronics |
|
20 / 37 page ![]() Operating description L8150 20/37 Figure 10. Rectangular Drive Pattern (Reverse) Smooth Drive mode is activated when three consecutive periods shorter than TMAX are detected and device will keep driving in Smooth mode until an external command is applied (through FR pin) or motor electrical period becomes longer than the maximum period the device is able to follow. Startup phase (rectangular driving) is activated in one of the following conditions: ● when the Period Counter saturates; ● when the desired rotation direction (coming from FR command) is different from the detected rotation direction; ● SD = High → Low During all working conditions a current limitation circuit is active. It is composed of a current comparator sensing current flowing in the sense resistor (usually a sense resistor is connected between the sources of all power low side driver transistors and ground) and of some control logic. Current limitation is achieved in three possible ways according to the different motor situations. The current limiter control method is a consequence of the rotation speed and the detected direction of the motor. Let's divide the possible situations in two different cases: 1. The motor is rotating and its frequency is lower than the one used to switch between rectangular and sinusoidal driving pattern 2. The motor is rotating and its frequency is bigger than the one used to switch between rectangular and sinusoidal driving pattern In case 1) even if the detected rotation direction is different from the desired direction, the current limiter control method is to force two phases to GND and one phase is left in high impedance state. In case 2) the possible situations can be the following: 2a) The desired direction is equal to the detected direction and sinusoidal mode is applied, the current limiter control method is forcing all the phases to GND HallU HallV HallW OutU OutV OutW HallU HallV HallW HallU HallV HallW OutU OutV OutW |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |