58 / 81 page ![]() DP83848-HT SLLSEJ7 – FEBRUARY 2015 www.ti.com Table 49. MII Interrupt Status and Miscellaneous Control Register (MISR), Address 0x12 BIT BIT NAME DEFAULT DESCRIPTION 15 RESERVED 0, RO RESERVED: Writes ignored, Read as 0 Energy Detect interrupt: 1 = Energy detect interrupt is pending and is cleared by the current 14 ED_INT 0, RO/COR read 0 = No energy detect interrupt pending Change of Link Status interrupt: 1 = Change of link status interrupt is pending and is cleared by the 13 LINK_INT 0, RO/COR current read 0 = No change of link status interrupt pending Change of speed status interrupt: 1 = Speed status change interrupt is pending and is cleared by the 12 SPD_INT 0, RO/COR current read 0 = No speed status change interrupt pending Change of duplex status interrupt: 1 = Duplex status change interrupt is pending and is cleared by the 11 DUP_INT 0, RO/COR current read 0 = No duplex status change interrupt pending Auto-Negotiation Complete interrupt: 1 = Auto-negotiation complete interrupt is pending and is cleared by 10 ANC_INT 0, RO/COR the current read 0 = No Auto-negotiation complete interrupt pending False Carrier Counter half-full interrupt: 1 = False carrier counter half-full interrupt is pending and is cleared by 9 FHF_INT 0, RO/COR the current read 0 = No false carrier counter half-full interrupt pending Receive Error Counter half-full interrupt: 1 = Receive error counter half-full interrupt is pending and is cleared 8 RHF_INT 0, RO/COR by the current read 0 = No receive error carrier counter half-full interrupt pending 7 RESERVED 0, RO RESERVED: Writes ignored, Read as 0 6 ED_INT_EN 0, RW Enable Interrupt on energy detect event 5 LINK_INT_EN 0, RW Enable Interrupt on change of link status 4 SPD_INT_EN 0, RW Enable Interrupt on change of speed status 3 DUP_INT_EN 0, RW Enable Interrupt on change of duplex status 2 ANC_INT_EN 0, RW Enable Interrupt on Auto-negotiation complete event 1 FHF_INT_EN 0, RW Enable Interrupt on False Carrier Counter Register half-full event 0 RHF_INT_EN 0, RW Enable Interrupt on Receive Error Counter Register half-full event 8.6.3.4 False Carrier Sense Counter Register (FCSCR) This counter provides information required to implement the “False Carriers” attribute within the MAU managed object class of Clause 30 of the IEEE 802.3u specification. Table 50. False Carrier Sense Counter Register (FCSCR), Address 0x14 BIT BIT NAME DEFAULT DESCRIPTION 15:8 RESERVED 0, RO RESERVED: Writes ignored, Read as 0 False Carrier Event Counter: 7:0 FCSCNT[7:0] 0, RO/COR This 8-bit counter increments on every false carrier event. This counter sticks when it reaches its max count (FFh). 58 Submit Documentation Feedback Copyright © 2015, Texas Instruments Incorporated Product Folder Links: DP83848-HT |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |