| поискавой системы для электроныых деталей |
|
AAT2500 датащи(PDF) 19 Page - Advanced Analogic Technologies |
|
|
|||||||||||||||||||||||||||||
AAT2500 датащи(HTML) 19 Page - Advanced Analogic Technologies |
|
19 / 26 page ![]() Thermal Calculations There are three types of losses associated with the AAT2500 step-down converter: switching losses, conduction losses, and quiescent current losses. Conduction losses are associated with the RDS(ON) characteristics of the power output switching devices. Switching losses are dominated by the gate charge of the power output switching devices. At full load, assuming continuous conduction mode (CCM), a simplified form of the step-down convert- er and LDO losses is given by: IQBUCK is the step-down converter quiescent cur- rent and IQLDO is the LDO quiescent current. The term tsw is used to estimate the full load step-down converter switching losses. For the condition where the buck converter is in dropout at 100% duty cycle, the total device dissi- pation reduces to: Since RDS(ON), quiescent current, and switching losses all vary with input voltage, the total losses should be investigated over the complete input voltage range. Given the total losses, the maximum junction tem- perature can be derived from the θJA for the TDFN/STDFN33-12 package which is 50°C/W. PCB Layout The following guidelines should be used to ensure a proper layout. 1. The input capacitor C2 should connect as closely as possible to VP and PGND, as shown in Figure 4. 2. The output capacitor and inductor should be connected as closely as possible. The connec- tion of the inductor to the LX pin should also be as short as possible. 3. The feedback trace should be separate from any power trace and connect as closely as possible to the load point. Sensing along a high-current load trace will degrade DC load regulation. If external feedback resistors are used, they should be placed as closely as pos- sible to the FB pin. This prevents noise from being coupled into the high impedance feed- back node. 4. The resistance of the trace from the load return to GND should be kept to a minimum. This will help to minimize any error in DC regulation due to differences in the potential of the internal sig- nal ground and the power ground. 5. For good thermal coupling, PCB vias are required from the pad for the TDFN/STDFN pad- dle to the ground plane. The via diameter should be 0.3mm to 0.33mm and positioned on a 1.2mm grid. 6. LDO bypass capacitor (C5) should be connected directly between pins 7 (BYP) and 8 (GND) TJ(MAX) = PTOTAL · ΘJA + TAMB PTOTAL = IOBUCK2 · RDSON(HS) + IOLDO · (VIN - VOLDO) + (IQBUCK + IQLDO) · VIN PTOTAL IOBUCK2 · (RDSON(HS) · VOBUCK + RDSON(LS) · [VIN - VOBUCK]) VIN = + (tsw · F · IOBUCK + IQBUCK + IQLDO) · VIN + IOLDO · (VIN - VOLDO) AAT2500 1MHz Step-Down Converter/LDO Regulator 2500.2006.05.1.16 19 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |