| поискавой системы для электроныых деталей |
|
L9918 датащи(PDF) 43 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9918 датащи(HTML) 43 Page - STMicroelectronics |
|
43 / 109 page ![]() BV8 RPM8 TJ8 F_T: Diagnosis flag for thermal fault, 1 bit F_M: Diagnosis flag for mechanical failure, 1 bit F_E: Diagnosis flag for electrical failure, 1 bit DCE5: Duty cycle value of the excitation PWM, 5 bits Table 50 EXC8: Measured excitation current, 8 bits Table 53 F_G: IEXC flag: current limitation flag, 1 bit (enabled by programming) F_H: LRC flag: LRC function flag, 1 bit (enabled by programming) X: Bit answered as “dominant”, 1 bit F_L1: Diagnosis flag for LIN error, 1 bit F_L0: Diagnosis flag LIN communication timeout, 1 bit A8: Adopted set point, 8bits BV8: Battery voltage measure, 8bits RPM8: Alternator rotation frequency measure, 8 bits TJ8: Junction temperature measure, 8 bits 5.3.7 Measurements filter 5.3.7.1 Excitation duty cycle Dc on excitation measure available by LIN Tx frames is optionally filtered with respect to actual Dc on excitation value. Filter parameters are configurable by NVM bit (DFM_FILTER_TP). 5.3.7.2 Iexc measurement filter Iexc measure available by LIN Tx frames is optionally filtered with respect to actual Iexc value. Filter parameters are configurable by NVM bits (IFELD_FILTER). 5.3.7.3 B+ measurement filter B+ voltage measure available by LIN Tx frames is optionally filtered with respect to actual B+ voltage value. Filter parameters are configurable by NVM bits (BF_FILT/BF_FILT2). 5.3.7.4 Regulation loop parameters L9918 regulation loop is conceived to be configured to meet the largest application requirements. Active parameter value (eg. LRC-rise, LRC-cut speed) is selected within pre-fixed set of values. Parameters Sets are typically stored in NVM. Default configuration (static configuration) provides a full set of regulation parameters. LIN Rx frame (dynamic configuration) can modify available set/value only for some of regulation parameters. 5.4 LIN Diagnostic frames Other than LIN frames listed in the previous paragraphs, L9918 supports further specific frames, implemented for diagnostic purposes. Diagnostic frames IDs are defined as listed below: • Master diagnostic frames: ID = 0x3C. These frames are sent by LIN master and they does not require answer from communication slave. • Slave response diagnostic frames: ID = 0x3D. These frame are structured similarly to LIN TX frames: LIN master sends the frame header and the slave is required to answer with data bytes. Diagnostic frames featured into L9918 are described in the following paragraphs. L9918 LIN Diagnostic frames DS13000 - Rev 2 page 43/109 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |