| поискавой системы для электроныых деталей |
|
ADM3050EBRIZ датащи(PDF) 7 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADM3050EBRIZ датащи(HTML) 7 Page - Analog Devices |
|
7 / 19 page ![]() Data Sheet ADM3050E Rev. B | Page 7 of 19 UL (Pending) CSA (Pending) VDE (Pending) CQC (Pending) Basic insulation at: 300 V rms mains, 780 V secondary (1103 VPEAK) Reinforced insulation at: 300 V rms mains, 390 V secondary (552 VPEAK) File E214100 File 205078 File 2471900-4880-0001 File (pending) 1 In accordance with UL 1577, each ADM3050E is proof tested by applying an insulation test voltage ≥ 6840 V rms for 1 sec. 2 In accordance with DIN V VDE V 0884-10, each product is proof tested by applying an insulation test voltage ≥ 1592 VPEAK for 1 sec (partial discharge detection limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval. ADM3050EBRIZ See Table 11 and the Insulation Lifetime section for the recommended maximum working voltages for specific cross isolation waveforms and insulation levels. The ADM3050EBRIZ is pending approval or approved by the organizations listed in Table 6. Table 6. UL (Pending) CSA (Pending) VDE (Pending) CQC (Pending) UL1577 Component Recognition Program1 Approved under CSA Component Acceptance Notice 5A DIN V VDE V 0884-10 (VDE V 0884-10):2006-122 Certified under CQC11- 471543-2012 Single Protection, 5700 V rms Isolation Voltage CSA 60950-1-07+A1+A2 and IEC 60950-1, second edition, +A1+A2: Reinforced insulation, 849 VPEAK, VIOTM = 8 kVPEAK GB4943.1-2011 Basic insulation at 780 V rms (1103 VPEAK) Basic insulation at 780 V rms (1103 VPEAK) Reinforced insulation at 390 V rms (552 VPEAK) Reinforced insulation at 390 V rms (552 VPEAK) IEC 60601-1 Edition 3.1: Basic insulation (1 MOPP), 490 V rms (686 VPEAK) Reinforced insulation (2 MOPP), 238 V rms (325 VPEAK) CSA 61010-1-12 and IEC 61010-1 third edition: Basic insulation at: 300 V rms mains, 780 V secondary (1103 VPEAK) Reinforced insulation at: 300 V rms mains, 390 V secondary (552 VPEAK) File E214100 File 205078 File 2471900-4880-0001 File (pending) 1 In accordance with UL 1577, each ADM3050E is proof tested by applying an insulation test voltage ≥ 6840 V rms for 1 sec. 2 In accordance with DIN V VDE V 0884-10, each product is proof tested by applying an insulation test voltage ≥ 1592 VPEAK for 1 sec (partial discharge detection limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval. DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS (PENDING) These isolators are suitable for reinforced electrical isolation only within the safety limit data. Protective circuits ensure the maintenance of the safety data. Table 7. ADM3050EBRWZ VDE Characteristics Description Test Conditions/Comments Symbol Characteristic Unit Installation Classification per DIN VDE 0110 For Rated Mains Voltage ≤ 150 V rms I to IV For Rated Mains Voltage ≤ 300 V rms I to IV For Rated Mains Voltage ≤ 600 V rms I to IV Climatic Classification 40/125/21 Pollution Degree per DIN VDE 0110, Table 1 2 Maximum Working Insulation Voltage Reinforced VIORM 849 VPEAK |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |