19 / 26 page ![]() SMS66 Preliminary Information Summit Microelectronics, Inc 2070 1.0 7/16/03 19 enable by writing other codes (not 0101BIN) to the write protection register. Writing to the write protection register is shown in Figure 7. CONFIGURATION REGISTERS The majority of the configuration registers are grouped with the general-purpose memory located at either slave address 1010BIN or 1011BIN. The bus address bits, A[1:0], used to differentiate the general-purpose memory from the configuration registers are set to 11BIN. Bus address bit A[2] can be programmed as either 0 or biased by the A2 pin. Two additional configuration registers are located at addresses 83HEX and 84HEX of slave address 1001BIN. Writing and reading the configuration registers is shown in Figures 8, 9, 10,11 and 12. GENERAL-PURPOSE MEMORY The 4k-bit general-purpose memory is located at either slave address 1010BIN or 1011BIN. The bus address bits, A[1:0], used to differentiate the general- purpose memory from the configuration registers are set to 00BIN for the first 2k-bits and 01BIN for the second 2k-bits. Bus address bit A[2] can be programmed as either 0 or biased by the A2 pin. The word address must be set each time the memory is accessed. Memory writes and reads are shown in Figures 13, 14 and 15. COMMAND AND STATUS REGISTERS The command and status registers are located at slave address 1001BIN. Writes and reads of the command and status registers are shown in Figures 16 and 17. ADC CONVERSIONS An ADC conversion on any monitored channel can be performed and read over the I 2C bus using the ADC read command. The ADC read command, shown in Figure 18, starts with a dummy write to the 1001BIN slave address. Bits [6:3] of the word address byte are used to address the desired monitored input. Once the device acknowledges the channel address, it begins the ADC conversion of the addressed input. This conversion requires 70 µs to complete. During this conversion time, acknowledge polling can be used. The SMS66 will not acknowledge the address bytes until the conversion is complete. When the conversion has completed, the SMS66 will acknowledge the address byte and return the 10-bit conversion along with the 4-bit channel address echo. GRAPHICAL USER INTERFACE (GUI) Device configuration utilizing the Windows based SMS66 graphical user interface (GUI) is highly recommended. The software is available from the Summit website (www.summitmicro.com). Using the GUI in conjunction with this datasheet and Application Note 33, simplifies the process of device prototyping and the interaction of the various functional blocks. A programming Dongle (SMX3200) is available from Summit to communicate with the SMS66. The Dongle connects directly to the parallel port of a PC and programs the device through a cable using the I 2C bus protocol. Slave Address Bus Address Register Type 1001BIN A2 A1 A0 Write Protection Register, Command and Status Registers, Two Configuration Registers, ADC Conversion Readout A2 0 0 1 st 2-k Bits of General-Purpose Memory A2 0 1 2 nd 2-k Bits of General-Purpose Memory 1010BIN or 1011BIN A2 1 1 Configuration Registers Table 1 - Address bytes used by the SMS66. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |