13 / 26 page ![]() SMS66 Preliminary Information Summit Microelectronics, Inc 2070 1.0 7/16/03 13 The SMS66 can be programmed to wait until either or both VDD and 12VIN inputs are within their respective voltage threshold limits before Power-on sequencing is allowed to begin. This ensures that the converters have their full supply voltage before they are enabled. Once Power-on sequencing begins, the SMS66 will wait a Power-on delay time (tDPON) for any channel in the first sequence position (0) and then activate the PUPX outputs for those channels. The Power-on delay times are individually programmable for each channel. The SMS66 will then wait until all VMX inputs of the channels assigned to the first sequence position (0) are above their programmed UV1 thresholds. At this point, the SMS66 will enter the second sequence position (1) and begin to timeout the Power-on delay times for the associated channels. This process continues until all of channels in the sequence have turned on and are above their UV1 threshold. The status registers indicates that all sequenced power supply channels have turned on. The programmable sequence termination timer can be used to protect against a stalled Power-on sequence. This timer resets itself at the beginning of each sequence position. All channels in the sequence position must go above their UV1 threshold before the sequence termination timer times out (tSTT) or the sequence will terminate and all PUPX outputs will be switched to their inactive state. The status registers contain bits that indicate the sequence has been terminated and in which sequence position the timer timed out. This timer has four settings of OFF, 100ms, 200ms and 400ms. While the SMS66 is in the Power-on sequencing mode the RST output is held active and the HEALTHY output is held inactive regardless of trigger sources. The Power-off and Force Shutdown trigger options are also disabled while in this mode. Furthermore, the SMS66 will not respond to activity on the PWR_ON/OFF pin or to a Power-off I 2C command during Power-on sequencing mode. MONITORING Once the Power-on sequence is complete and before a Power-off sequence has been initiated, the SMS66 continues to monitor all VMX inputs, the VDD and 12VIN inputs, and two temperature sensor inputs with a 10-bit ADC. Each of these inputs is sampled and converted by the ADC every 2ms. The ADC input has a range of 0V to four times the voltage on VREF_ADC for inputs VMA-F and the VDD input. The range is extended to 12 times VREF_ADC for the 12VIN input and is reduced to two times VREF_ADC for the AIN1 and AIN2 inputs. The SMS66 monitors internal temperature using the 10-bit ADC and the automonitor function. Two under temperature and two over temperature thresholds can be set, each with its own programmable trigger options and consecutive conversion before trigger counter. Resolution is 0.25 C per bit scaled over the range of -128 C to 127.75 C. The temperature value can also be acquired over the I 2C bus as a 10-bit signed two's complement value. The SMS66 compares each resulting ADC conversion with two programmable 10-bit under-voltage limits (UV1, UV2) and two programmable 10-bit over-voltage limits (OV1, OV2) for the corresponding input. A consecutive conversion counter is used to provide filtering of the ADC inputs. Each limit can be programmed to require 1, 2, 4 or 6 consecutive out-of- limit conversions before it is said to be in fault. One in- limit conversion will remove the fault from the threshold limit. This provides digital filtering of the monitored inputs. The ADC inputs VMA-F can use additional filtering by connecting a capacitor from the corresponding CAPX pins to ground to form an analog RC filter (R=25k Ω). The input is considered to be in a fault condition if any of its limit thresholds are in fault. Setting an OV threshold limit to full-scale (3FFHEX), or setting an UV threshold limit to 000HEX ensures that the limit can never be in fault. The status registers provide the real-time status of all monitored inputs. The voltage threshold limits for inputs VMA-F, VDD and 12VIN can be programmed to trigger the RST and HEALTHY outputs as well as a Force Shutdown and Power-off operation when exceeded. The threshold limits for the internal temperature sensor and the AIN1 and AIN2 inputs can be programmed to trigger the RST, HEALTHY, and FAULT outputs. APPLICATIONS INFORMATION (CONTINUED) |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |