16 / 25 page ![]() – – – – 26 27 200 – PowerManagement This command sets the power mode to Full Power, Adaptive Trickle Power, or Push-to-Fix mode. Figure 29 contains the values for the following example to set the receiver to Adaptive Trickle Power mode: $PLSC,200,2,200,3000,300000,30000*0D Figure 28: Power Management Command Example Power Management Command Example1 Name Example Units Description MID $PLSC,200 Message ID Mode 2 See Figure 30 OnTime 200 (200 – 900) ms Must be a multiple of 100 (if not, it is rounded up to the nearest multiple of 100). Set this to 0 when Mode = 3. LP Interval 3000 (1000 – 10000) ms Must be an integer value ≥1000 and ≤10000. Set this to 0 when Mode = 3. MaxAcqTime 300000 ( ≥1000) ms When Adaptive Trickle Power is enabled, this is the maximum allowable time from the start of a power cycle to the time a valid position fix is obtained. If no fix is obtained in this time, the receiver is deactivated for up to MaxOffTime, and a hot start is commanded when the receiver reactivates. The integer must be in multiples of 1000ms. There is no upper limit. MaxOffTime 30000 (1000 – 1800000) ms The longest period (in mS) for which the receiver deavtivates due to the MaxAcqTime timeout. The actual deactivated period may be less if the user-specified duty cycle (OnTime / LpInterval) can be maintained. PushToFixPeriod (10 – 7200) sec The receiver automatically awakens every Push-to-Fix period to obtain a position fix, collect ephemeris (if needed), and calibrate the real-time clock (RTC) (if needed). Checksum *0D <CR> <LF> End of message termination 1. Default setting is full power; trickle power disabled. Mode Values Value Description 0 Ask the receiver to send the current power mode 1 Set the receiver to Full Power mode 2 Set the receiver to Adaptive Trickle Power mode 3 Set the receiver to Push-to-Fix mode Figure 29: Power Management Command Example Figure 30: Power Management Mode Values The receiver outputs a response to this command. Figure 31 contains the response for the above command: $PLSR,200,1,2,300,1000,300000,30000*02 For some further examples of this command: Query the power management mode Input command: $PLSC,200,0*0E Output response: $PLSR,200,1,1*03 Set the receiver to Full Power mode Input command: $PLSC,200,1*0F Output response: $PLSR,200,1,1*03 Set the receiver to Adaptive Trickle Power mode Input command: $PLSC,200,2,900,10000,300000,30000*34 Output response: $PLSR,200,1,2,900,10000,300000,30000*38 Set the receiver to Push-to-Fix Power mode Input command: $PLSC,200,3,0,0,300000,30000,7200*14 Output response: $PLSR,200,1,3,300000,30000,7200*18 Power Management Response Example Name Example Units Description MID $PLSC,200 Message ID Valid 1 0: command invalid, 1:command valid Mode 2 See Figure 30 OnTime 200 ms Displayed when mode = 2 LP Interval 3000 ms Displayed when mode = 2 MaxAcqTime 300000 ms Displayed when mode = 2 or 3 MaxOffTime 30000 ms Displayed when mode = 2 or 3 PushToFixPeriod sec Displayed when mode = 3 Checksum *01 <CR> <LF> End of message termination Figure 31: Power Management Response Example |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |