| поискавой системы для электроныых деталей |
|
USB5926C/KD датащи(PDF) 45 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
USB5926C/KD датащи(HTML) 45 Page - Microchip Technology |
|
45 / 65 page ![]() USB5926C DS00003190B-page 45 2019 - 2021 Microchip Technology Inc. 8.8.2 BILLBOARD ENDPOINT FUNCTIONALITY When the applicable GPIOx pin is 0, which indicates that Billboard device must be displayed, the following sequence of events will occur: 1. USB5926C will force the Hub Feature Controller internal device to disconnect from the USB Hub port (emulating a physical detach) 2. USB5926C will force the Hub Feature Controller to re-connect with descriptors that will show the Hub Feature Controller endpoint is a Billboard device, compliant to version 1.1 of the Billboard device class specification. 3. USB5926C will start a timer (Timer A) when the Host sets the Hub Feature Controller USB address. This timer will be used to ensure that the Billboard endpoint will not remain permanently attached if it is never accessed. The default Timer A timeout is 20 seconds. 4. This implementation will only support Billboard when a failure occurs, therefore the Device Container uses a static list of device capabilities and will only expose the Billboard Device on failure to enter into Modal Operation and will set the bmConfigured descriptor field to “Unspecified Error” (00b) by default. 5. The Hub Feature Controller will Provide the iAlternateModeString when the host requests it, and will start a timer (Timer B). The default Timer B timeout is 20 seconds. 6. When either timer expires, the USB5926C will force the Hub Feature Controller internal device to disconnect from the USB Hub port (emulating a physical detach). 7. USB5926C will force the Hub Feature Controller to re-connect with the standard Hub Feature Controller Func- tionality. TABLE 8-11: TIMER A: BILLBOARD DETACH TIMER LSB DETACH_TIMER_A_LSB (413Ch) Billboard Detach Timer A LSB BIT Name R/W Description 7:0 TIMEOUT R/W Timer A is started as soon as the Hub Feature Controller’s Billboard Class Device address is set by the host. Once the timer expires, the Billboard Class Device will automatically detach from the host and re- attach as the default WinUSB device. Increments of 10ms can be set. The default value of 413Ch = D0h, 413Dh = 07h is equivalent to a 20s timeout. (07D0h = 2000d) TABLE 8-12: TIMER A: BILLBOARD DETACH TIMER MSB DETACH_TIMER_A_MSB (413Dh) Billboard Detach Timer A MSB BIT Name R/W Description 7:0 TIMEOUT R/W Timer A is started as soon as the Hub Feature Controller’s Billboard Class Device address is set by the host. Once the timer expires, the Billboard Class Device will automatically detach from the host and re- attach as the default WinUSB device. Increments of 10ms can be set. Note: The default value of 413Ch = D0h, 413Dh = 07h is equiv- alent to a 20s timeout. (07D0h = 2000d) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |