поискавой системы для электроныых деталей
  Russian  ▼
ALLDATASHEETRU.COM

X  

MAX16050EVKIT датащи(PDF) 3 Page - Maxim Integrated Products

номер детали MAX16050EVKIT
подробное описание детали  Reverse-Sequencing Operation
PDF  13 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  MAXIM [Maxim Integrated Products]
домашняя страница  https://www.maximintegrated.com/en.html
Logo MAXIM - Maxim Integrated Products

MAX16050EVKIT датащи(HTML) 3 Page - Maxim Integrated Products

  MAX16050EVKIT Datasheet HTML 1Page - Maxim Integrated Products MAX16050EVKIT Datasheet HTML 2Page - Maxim Integrated Products MAX16050EVKIT Datasheet HTML 3Page - Maxim Integrated Products MAX16050EVKIT Datasheet HTML 4Page - Maxim Integrated Products MAX16050EVKIT Datasheet HTML 5Page - Maxim Integrated Products MAX16050EVKIT Datasheet HTML 6Page - Maxim Integrated Products MAX16050EVKIT Datasheet HTML 7Page - Maxim Integrated Products MAX16050EVKIT Datasheet HTML 8Page - Maxim Integrated Products MAX16050EVKIT Datasheet HTML 9Page - Maxim Integrated Products Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 13 page
background image
MAX16050 Evaluation Kit
_______________________________________________________________________________________
3
Detailed Description of Hardware
The MAX16050 evaluation kit (EV kit) evaluates the 4-
channel MAX16050 and 5-channel MAX16051 power-
supply sequencing ICs. The MAX16050 EV kit monitors
up to nine DC-DC converter outputs, thus ensuring
proper power-up and power-down conditions for sys-
tems requiring voltage sequencing. During power-
down, the outputs can be reverse-sequenced by
driving SHDN low. The MAX16050 EV kit’s VCC power-
supply inputs require 2.7V to 13.2V and VPULLUP
requires 2.2V to 5.5V.
The MAX16050 EV kit can operate in DC-DC mode or in
demo mode. DC-DC mode uses the MAX16050 and
MAX16051 to control external DC-DC converters, and
without demo mode facilitates stand-alone evaluation
without external DC-DC converters.
The EV kit features RESET output signals to indicate an
undervoltage condition, or when shunts are installed
across the jumpers labeled SHDN or FAULT.
Additionally, dedicated OV_OUT outputs indicate over-
voltage faults when any of the monitored EV kit IN inputs
go above their overvoltage thresholds. The EV kit also
provides test points OUTPUT1 and OUTPUT2 for low-cur-
rent n-channel MOSFETs N1 and N2, respectively, which
are controlled by the MAX16050 and MAX16051 charge-
pump outputs. Refer to the MAX16050/MAX16051 IC
data sheet for additional information on selecting appro-
priate MOSFETs when driving external MOSFETs using
the charge-pump outputs.
Power-Supply Connections
(U1_VCC, U2_VCC, VPULLUP)
The MAX16050 EV kit requires input voltages of 2.7V to
13.2V connected at the U1_VCC and U2_VCC test
points to power the MAX16050 and MAX16051 con-
trollers, respectively. The power supplies must provide
at least 50mA of current. VPULLUP requires an input
voltage of 2.2V to 5.5V connected to the VPULLUP test
point and supplies power to the EV kit’s pullup resistor
open-drain outputs. The VPULLUP power supply must
provide at least 50mA of current. Additional surface-
mount 1206 PCB pads are provided for adding addition-
al bulk capacitance at C1, C2, and C12 for the EV kit
power-supply inputs. Header pins J3–J6 are available to
use as ground reference for signal and voltage probing.
Table 1. MAX16050/MAX16051 EV Kit Jumper Description
JUMPER
MAX16050
MAX16051
SIGNAL
SHUNT
POSITION
FUNCTION
1-2*, 2-3
Demo mode (see Figure 1)
J1
J2
EV kit operation
2-3 only
DC-DC mode (see Figure 1)
1-2
OUT_ connects to VCC through resistor
JU1
JU10
OUT_
2-3*
OUT_ connects to VPULLUP through resistor
1-2*
Controllers enabled at U1_VCC/U2_VCC > 3.2V
JU2
JU11
EN
2-3
Controllers disabled
1-2
Connects to CP_OUT through resistor
JU3
JU12
OUT3
2-3*
Connection dependent on jumpers JU1 and JU10
configuration
JU4
SEQ1
Not installed*
JU5
SEQ2
Not installed*
JU6
SEQ3
Not installed*
Sequence order: OUT1, OUT2, OUT3, OUT4
1-2*
Normal operation of EN and SHDN functions
JU7
JU15
EN_HOLD
2-3
Ignores high-to-low transitions at SHDN and EN
Not installed*
Controller enabled or externally driven
JU8
JU13
SHDN
Installed
Controllers disabled. Reverse power-down sequencing.
RESET asserts low.
Not installed*
Normal operation
JU9
JU14
FAULT
Installed
Disables controller. Initiates simultaneous power-down of
OUT. RESET asserts low.
*Default position (demo mode operation).



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com