| поискавой системы для электроныых деталей |
|
MAX16050EVKIT датащи(PDF) 6 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX16050EVKIT датащи(HTML) 6 Page - Maxim Integrated Products |
|
6 / 13 page ![]() EN_HOLD (JU7, JU15) Jumpers JU7 and JU15 configuration setting allows the MAX16050 and MAX16051 to ignore high-to-low transi- tions at the EN and SHDN inputs. Place a shunt across pins 1-2 for normal operation of the EN and SHDN fea- ture. Place a shunt across pins 2-3 to ignore high-to-low transitions at EN and SHDN. See Table 7 for jumpers JU7 and JU15 configuration. SHDN Control (JU8, JU13) Jumpers JU8 and JU13 initiate the MAX16050 and MAX16051 for a reverse-sequencing event. Install shunts on jumpers JU8 and JU13 to initiate a reverse- sequencing event. Remove the shunts at jumpers JU8 and JU13 for proper power-up operation when EN = high. To drive SHDN externally, place a square-wave signal with a 2V to 5.5V logic-high level at pin 1 of jumpers JU8 or JU13. See Table 8 for jumpers JU8 and JU13 configuration. FAULT Control (JU9, JU14) Jumpers JU9 and JU14 control the MAX16050 and MAX16051 input/output FAULT signal, respectively. FAULT asserts low when any of the monitored IN volt- ages fall below its SET voltage threshold. As an output, FAULT can be driven externally to initiate a simultane- ous power-down of the DC-DC controllers. Install a shunt across jumpers JU9 and JU14 to initiate a shut- down of the controllers. To drive FAULT externally, place a square-wave signal with a 2V to 5.5V logic-high level at pin 1 of jumpers JU8 or JU14. Connect the sig- nal ground to a convenient ground reference. See Table 9 for jumpers JU9 and JU14 configuration. MAX16050 Evaluation Kit 6 _______________________________________________________________________________________ Table 8. Jumpers JU8, JU13 Configuration SHUNT POSITION SHDN INPUT SETTING Not installed Controller enabled or externally driven Installed Reverse power-down sequencing. RESET asserts low. Table 9. Jumpers JU9, JU14 Configuration SHUNT POSITION FAULT INPUT SETTING Not installed Normal operation Installed Disables controller. Initiates simultaneous power down of OUT_. RESET asserts low. Table 7. Jumpers JU7, JU15 Configuration SHUNT POSITION EN_HOLD INPUT SETTING 1-2 Normal operation of EN and SHDN functions 2-3 Ignores high-to-low transitions at EN and SHDN Table 6. MAX16050 Sequencing Control (JU4, JU5, JU6) (continued) SHUNT POSITION SEQUENCE ORDER JU4 JU5 JU6 1ST 2ND 3RD 4TH 2-3 Not installed Not installed U1_OUT2 U1_OUT3 U1_OUT4 U1_OUT1 2-3 Not installed 2-3 U1_OUT2 U1_OUT4 U1_OUT1 U1_OUT3 2-3 Not installed 1-2 U1_OUT2 U1_OUT4 U1_OUT3 U1_OUT1 2-3 2-3 Not installed U1_OUT3 U1_OUT1 U1_OUT2 U1_OUT4 2-3 2-3 2-3 U1_OUT3 U1_OUT1 U1_OUT4 U1_OUT2 2-3 2-3 1-2 U1_OUT3 U1_OUT2 U1_OUT1 U1_OUT4 2-3 1-2 Not installed U1_OUT3 U1_OUT2 U1_OUT4 U1_OUT1 2-3 1-2 2-3 U1_OUT3 U1_OUT4 U1_OUT1 U1_OUT2 2-3 1-2 1-2 U1_OUT3 U1_OUT4 U1_OUT2 U1_OUT1 1-2 Not installed Not installed U1_OUT4 U1_OUT1 U1_OUT2 U1_OUT3 1-2 Not installed 2-3 U1_OUT4 U1_OUT1 U1_OUT3 U1_OUT2 1-2 Not installed 1-2 U1_OUT4 U1_OUT2 U1_OUT1 U1_OUT3 1-2 2-3 Not installed U1_OUT4 U1_OUT2 U1_OUT3 U1_OUT1 1-2 2-3 2-3 U1_OUT4 U1_OUT3 U1_OUT1 U1_OUT2 1-2 2-3 1-2 U1_OUT4 U1_OUT3 U1_OUT2 U1_OUT1 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |