| поискавой системы для электроныых деталей |
|
OMR50M-R300-UEP-V1 датащи(PDF) 3 Page - Pepperl+Fuchs Inc. |
|
|
|||||||||||||||||||||||||||||
OMR50M-R300-UEP-V1 датащи(HTML) 3 Page - Pepperl+Fuchs Inc. |
|
3 / 4 page ![]() Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com Measuring sensor with multiple switch points OMR50M-R300-UEP-V1 3 Intended Use Mounting instructions: The sensor can be mounted directly with thru-holes or by using a fixing bracket or mounting clamp (not included in the scope of delivery). Ensure that the surface is level in order to prevent the housing from becoming distorted when the fittings are tightened. It is advisable to secure the nuts and screws to prevent the sensor from being misaligned. Connection: Connect the device as set out in the connection diagram. Adjustment: The green LED lights up when the operating voltage is applied. Adjust the sensor so that the light spot is on the center of the reflector. Installation Note A pressure equalization membrane is fitted on the sensor nameplate. When mounting, make sure that the pressure equalization membrane is not sealed off. Teach-in Use the rotary switch for switching signal Q1 to select the relevant switching threshold A and/or B to teach in. The yellow LEDs indicate the current state of the selected output. To teach in a switching threshold, press and hold the "SET" button until the yellow and green LEDs flash in phase (approx. 1 s). Teach-in starts when the "SET" button is released. Successful Teach-in is indicated by the yellow and green LEDs flashing alternately (2.5 Hz). An unsuccessful Teach-in is indicated by the yellow and green LEDs rapidly flashing alternately (8 Hz). After an unsuccessful Teach-in, the sensor continues to operate with the previous valid setting after the relevant visual fault signal is issued. Different switching modes can be defined by teaching in the relevant distance data for switching thresholds A and B. Single-point operation: Window operation: Every taught-in switching threshold can be retaught (overwritten) by pressing the "SET" button again. A taught-in value can be reset by pressing the "SET" button for > 4 s. The yellow and green LEDs go out simultaneously to indicate that this procedure has been completed. The reset process starts when the "SET" button is released. A successful reset is indicated by the yellow and green LEDs flashing alternately (2.5 Hz).The minimum and maximum values for analog output Q2 are taught in in the same way as for the switching output: The following values apply: A = 0 V B = 10 V Curves/Diagrams Reflector type Reflector-dependent effective operating distances Distance X [m] H160 OFR-100/100 H50 C110 H100 OFR-500/500 3 x H100 0 5 10 15 20 25 30 35 40 45 50 50 m 35 m 28 m 25 m 20 m 0.2 m 50 m 0.2 m 0.2 m 0.2 m 0.2 m 0.2 m 9 m 0.2 m B A leer A B leer BA A > B AB B > A |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |