19 / 35 page ![]() 4.17 Voltage Regulator The voltage regulator generates 3.3 V and 5 V for internal circuitry. These voltages are derived from VMAIN supply. To use the internal voltage regulator connect: • VAUX5 to DRV_VAUX5 • VAUX3P3 to VAUX3P3_INT There are three options to reduce the managers’ power dissipation by regulating voltage outside the chip. • Use an external NPN transistor to regulate the 5 V. In this setup, the configuration of regulators pins should be as follows. – DRV_VAUX5 is connected to NPN BASE – VAUX5 is connected to NPN EMITTER (Connect Collector to VMAIN) – VAUX3P3 is connected to VAUX3P3_INT • Supply the manager with an external 5 V voltage regulator. In this setup, regulators pins configuration should be as follows. – VAUX3P3 is connected to VAUX3P3_INT – DRV_VAUX5 is not connected (left open) – VAUX5 is connected to external 5 V • Supply the manager with an external 3.3 V voltage regulator. In this setup, regulators pins configuration should be as follows. – VAUX5 is connected to DRV_VAUX5 – VAUX3P3_INT is not connected (left open) – VAUX3P3 is connected to external 3.3 V 4.18 SPI Communication The following table lists the SPI communication packet structure. Table 4-1. SPI Communication—Packet Structure Control Byte Selects Manager According to Address R/W Bit Internal Register Address Number of Words (Read Access Only) Data Written to IC (Write Access Only) Read from IC (Read Access Only) 8 bits R(0)/W(1) 8 bits 8 bits 16 bits 4.18.1 SPI Addressing The manager operates in the 8-bit address and 16-bit data. It responds to SPI transaction if the first SPI byte (IC address byte bits[7:1]) complies with the following. Table 4-2. Manager SPI Addressing 3 Bits (bit 7:5) 4 Bits (bit 4:1) 1 Bit (bit 0) 000 Address Input Pin Read/Write 4.18.2 Broadcast A broadcast command is intended to instruct all connected manager ICs to perform a specific operation. The broadcast command is a write command with the standard packet structure. In a broadcast read operation, the read data is not valid and the read operation has no impact. PD69208T4/PD69204T4/PD69208M Application Information © 2020 Microchip Technology Inc. Datasheet DS00003428C-page 19 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |