LM3370 датащи(PDF) 15 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
LM3370 датащи(HTML) 15 Page - National Semiconductor (TI) |
|
15 / 23 page ![]() I 2C Compatible Interface Electrical Specifications Unless otherwise noted, V BATT = 2.7V to 5.5V. Typical values and limits appearing in normal type apply for TJ = 25˚C. Limits appearing in boldface type apply over the entire junction temperature range for operation, −30˚C to +125˚C. (Notes 2, 8, 9) Symbol Parameter Conditions Min Typ Max Units F CLK Clock Frequency 400 kHz t BF Bus-Free Time between Start and Stop (Note 10) 1.3 µS t HOLD Hold Time Repeated Start Condition (Note 10) 0.6 µS t CLKLP CLK Low Period (Note 10) 1.3 µS t CLKHP CLK High Period (Note 10) 0.6 µS t SU Set Up Time Repeated Start Condition (Note 10) 0.6 µS t DATAHLD Data Hold Time (Note 10) 200 nS t CLKSU Data Set Up Time (Note 10) 200 nS T SU Set Up Time for Start Condition (Note 10) 0.6 µS T TRANS Maximum Pulse Width of Spikes that Must be Suppressed by the Input Filter of Both DATA & CLK signals. (Note 10) 50 nS VDD_I 2CI2C Logic High Level 1 V IN V I 2C Compatible Interface In I 2C compatible mode, the SCL pin is used for the I2C clock and the SDA pin is used for the I 2C data. Both these signals need a pull-up resistor according to I 2C specification. The values of the pull-up resistor are determined by the capaci- tance of the bus (typ. ∼1.8k). Signal timing specifications are according to the I 2C bus specification. Maximum frequency is 400 kHz. I 2C COMPATIBLE DATA VALIDITY The data on SDA line must be stable during the HIGH period of the clock signal (SCL). In other words, state of the data line can only be changed when CLK is LOW. 20167306 I 2C COMPATIBLE START AND STOP CONDITIONS START and STOP bits classify the beginning and the end of the I 2C session. START condition is defined as SDA signal transitioning from HIGH to LOW while SCL line is HIGH. STOP condition is defined as the SDA transitioning from LOW to HIGH while SCL is HIGH. The I 2C master always generates START and STOP bits. The I 2C bus is considered to be busy after START condition and free after STOP con- dition. During data transmission, I 2C master can generate repeated START conditions. First START and repeated START conditions are equivalent, function-wise. 20167307 www.national.com 15 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |